Installation Instructions

INSTALLATION
NOTE: When installing a leg-supported seat, the guide bracket is not required. The two
upper mounting brackets are centered on the 2" x 6" blocking with the four legs sitting
firmly on the floor. All four legs have adjustable feet with lock nuts. Adjust the front two
feet to achieve an approximate 3° rise at the front. Once adjusted, tighten the lock
nut to prevent future slipping.
STEP 1:
Locate the desired seat position making sure that the top of the seat is
between 17" 19" from the finished floor. When measuring, the seat must be in
the down, usable position. With a 24" level check from side-to-side and front-
to-back to ensure that the seat is level. A slight – 3° rise on the seat from the
back wall to the front of the seat is recommended.
STEP 2:
Use a pencil and mark the three screw holes from both upper mounting brackets.
Then mark the three holes from the guide bracket. Be careful of its position, the
bottom screw of the guide bracket needs to be centered on the middle wall stud
with the two top screws fastened to the 2" x 6". (as shown in Fig. 2)
STEP 3:
Remove the seat. In each of your marked locations, drill
1
/
4
" clearance holes through
the tile only. Then drill
3
/
16
" pilot holes through the header board and attach the
seat using
1
/
4
" x 3" stainless steel lag screws and fender washers. Use a generous
amount of silicone caulk to prevent water seepage into the mounting holes.
STEP 4:
Make sure the seat raises and lowers smoothly. If installed correctly, the seat will
remain in the “up” position by itself and will take little effort to lower it.
CARE & CLEANING
SUB-FLOOR
MAX.
HEIGHT
11
1
/
2
" REF.
19"
13
1
/
4
"
2
1
/
4
"
5
3
/
4
"
26" & 32"
7
1
/
4
"
6
5
/
8
"
1
3
/
4
"
1"
1
1
/
8
"
2"
Fold-Down Seat Mounting Location for Mustee DURABASE
®
Shower Floor
To clean, wipe seat down
with mild soap and water.
INSTALLATION QUESTIONS
Questions on the installation
or missing parts, call
216-267-3100 or e-mail
customerservice@mustee.com
for assistance. Hours of
operation are Monday to Friday,
8:30 a.m. to 4:30 p.m. E.S.T.
Please have the installation
manual available when
calling. DO NOT RETURN
PRODUCT TO THE PLACE
OF PURCHASE.
PREPARATION: (continued)
EXISTING WALL INSTALLATION:
Locate
stud behind the existing shower wall to
determine where the Fold-Down Padded
Seat can be safely mounted. Both the
upper mounting bracket and guide bracket
must be in contact with studwall.
Clean that portion of the shower wall
where the Fold-Down Seat will be installed.
Wall Studs, Typically 16" on Center
2" x 6"
Blocking
Center at 13
1
/
4
"
(to achieve
17" 19"
seat height)
13
1
/
4
"
16" 16"
17" to 19"
Top of seat
to finished
floor
9
1
/
2
"
to
11
1
/
2
"
3" to 5"
1"
Fig. 1a
Fig. 1b
Fig. 2
Pr eferre d by t he P ros”
As a company committed to continuous improvement, the specifications
in this installation manual are subject to change without notice.
SI-222 (01-10)
Patented and patents pending. Made and Printed in U.S.A.
ELM-235 CG_Seats SI-222_R14.indd 2 1/14/10 2:47:52 PM