User's Manual
Table Of Contents
- Radio Overview
- Controls & Display
- General Operation
- 3.1 Basic Operation
- 3.1.1 Turning Power ON and Setting Volume
- 3.1.2 Persistent Settings
- 3.1.3 Power-Up Password
- 3.1.4 Speaking into the Microphone
- 3.1.5 Display Backlight Control
- 3.1.6 Display Viewing Angle & Contrast Adjust (Standard Control Head Only)
- 3.1.7 Zone / Channel Display and Select
- 3.1.8 Setting Squelch Control
- 3.1.9 Zone Edit
- 3.1.10 Transmit Disable
- 3.1.11 Operation At Extended Range
- 3.1.12 Preventing Vehicle Battery Discharge
- 3.1.13 Cleaning the Control Head
- 3.1.14 Radio Service
- 3.2 Single Touch
- 3.2.1 Single Touch Buttons
- 3.2.2 Detailed Single Touch Operation
- 3.2.2.1 Conventional Unit Call
- 3.2.2.2 Conventional Call Alert
- 3.2.2.3 Conventional Status
- 3.2.2.4 Conventional Message
- 3.2.2.5 P25 Unit Call
- 3.2.2.6 P25 Call Alert
- 3.2.2.7 P25 Status
- 3.2.2.8 P25 Interconnect
- 3.2.2.9 SNSZ Unit Call
- 3.2.2.10 SNSZ Call Alert
- 3.2.2.11 SNSZ Status
- 3.2.2.12 SNSZ Message:
- 3.2.2.13 SNSZ Interconnect:
- 3.3 Radio Inhibit
- 3.4 Setting Squelch
- 3.5 Operating Modes
- 3.1 Basic Operation
- Radio Wide Features
- 4.1 Option Buttons
- 4.2 Menu Mode
- 4.3 Time-Out Timer
- 4.4 Home Channel Select
- 4.5 Power Output Select
- 4.6 Alert Tone Select
- 4.7 Ignition Power Down Duration
- 4.8 Horn Alert
- 4.9 Microphone Off-Hook Detect
- 4.10 Surveillance Mode
- 4.11 Public Address
- 4.12 Scanning
- 4.13 Scan Lists
- 4.14 Over the Air Programming
- 4.15 Over the Internet Programming
- 4.16 Auto / Unmute
- 4.17 Location Services
- 4.18 Emergency Alarm Receive Indicator
- 4.19 Kiosk Mode
- 4.20 Analog Noise Reduction
- Conventional Mode Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit / Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Channel Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF / ANI Signaling
- 5.13 Project 25 Mode Features
- 5.13.1 Digital Unit ID
- 5.13.2 Talkgroup ID
- 5.13.3 Network Access Code (NAC)
- 5.13.4 EFJohnson System Out-of-Range Indicator
- 5.13.5 EFJohnson System Automatic Registration
- 5.13.6 P25 Group Calls
- 5.13.7 P25 Unit Calls
- 5.13.8 P25 Conventional Telephone Calls
- 5.13.9 Call Alert
- 5.13.10 Call History
- 5.13.11 Messaging
- 5.13.12 Status Messaging
- 5.13.13 P25 Packet Data
- 5.14 Keypad Programming
- 5.15 Text Messaging
- SMARTNET / SmartZone / P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Unit Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET / SmartZone / P25 Trunking Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 P25 Radio Unit Monitor
- 6.14 SmartZone and P25 Trunking Unique Features
- 6.14.1 Busy Override
- 6.14.2 Site Trunking
- 6.14.3 Determining Current Site and Searching for a New Site
- 6.14.4 Locking / Unlocking a Site
- 6.14.5 Auto Site Search
- 6.14.6 P25 Wide Area Scan
- 6.14.7 Normal P25 and SmartZone Control Channel Hunt
- 6.14.8 Talkgroup Steering through System Access Permissions
- 6.14.9 Radio Information
- 6.14.10 Current Software version in the radio
- 6.15 P25 Trunking System Single Touch
- 6.16 P25 Messaging
- Secure Communication (Encryption)
- Data Features
- Tones & Error Messages
- Service Information
Draft 02 - Sep 1 2015
4-22 Viking Mobile Radio Operating Manual
Radio Wide Features
4.18 Emergency Alarm Receive Indicator
The Emergency Alarm Rx feature allows a user to receive an Emergency Alarm display
and/or alert on their radio when another radio on the same system sends out an
Emergency. This feature is supported in both P25 and SmartNet/SmartZone systems. On
SmartNet/SmartZone systems the Emergency Alarm can only be received on a radio with
the same Talkgroup as the sending radio. On P25 systems the Emergency Alarm can be
received by any radio on the same system.
When an Emergency Alarm is received the radio will either sound an alert tone, display
the sending radio’s ID or Alias, or do both depending on the settings programmed. When
received, the display context of the radio is changed to display “EA Received” on the top
line and either the ID or the Alias of the radio who sent the Emergency Alarm. If the
received ID is in the Call List, then the Alias will be displayed. If it is not, the ID will be
displayed.
An Emergency Alarm will not be received when the radio is active on a voice channel, in
Emergency, or in Radio Wide Scan Mode. Also, if in Surveillance mode, the backlight
will not turn on when an Emergency Alarm is received.
When received, the display context of the radio is changed to display “EA Received” on
the top line and either the ID or the Alias of the radio who sent the Emergency Alarm. If
the received ID is in the Call List, then the Alias will be displayed. If it is not, the ID will
be displayed.
After an Emergency Alarm has been received, any press of a button (except for the PTT)
will exit the display and clear the ten-second timer. If no buttons are pressed, the display
will continue to show “EA Received” along with the ID or Alias for ten seconds.
However, the alert tone is only heard once upon receiving the alarm. There is also a timer
that will not allow the radio to receive another Emergency Alarm from the same ID for
twenty seconds. This timer is only cleared on a channel change, zone change, or after
twenty seconds has expired.
Periodic PTT* This trigger happens every time the user presses PTT. This trigger is
activated when the user presses the PTT button but the data will
usually be sent after the call is over. We do this to avoid delaying the
call.
Periodic Emergency* This trigger happens every time the user puts the radio into
emergency.
Periodic Distance* This trigger happens every time the user moves the radio a distance
defined in the Triggered-Location-Request.
* Programmable in Armada.
Table 4.5 Supported Triggers
Trigger Description