User's Manual
Table Of Contents
- Radio Overview
- Controls & Display
- General Operation
- 3.1 Basic Operation
- 3.1.1 Turning Power ON and Setting Volume
- 3.1.2 Persistent Settings
- 3.1.3 Power-Up Password
- 3.1.4 Speaking into the Microphone
- 3.1.5 Display Backlight Control
- 3.1.6 Display Viewing Angle & Contrast Adjust (Standard Control Head Only)
- 3.1.7 Zone / Channel Display and Select
- 3.1.8 Setting Squelch Control
- 3.1.9 Zone Edit
- 3.1.10 Transmit Disable
- 3.1.11 Operation At Extended Range
- 3.1.12 Preventing Vehicle Battery Discharge
- 3.1.13 Cleaning the Control Head
- 3.1.14 Radio Service
- 3.2 Single Touch
- 3.2.1 Single Touch Buttons
- 3.2.2 Detailed Single Touch Operation
- 3.2.2.1 Conventional Unit Call
- 3.2.2.2 Conventional Call Alert
- 3.2.2.3 Conventional Status
- 3.2.2.4 Conventional Message
- 3.2.2.5 P25 Unit Call
- 3.2.2.6 P25 Call Alert
- 3.2.2.7 P25 Status
- 3.2.2.8 P25 Interconnect
- 3.2.2.9 SNSZ Unit Call
- 3.2.2.10 SNSZ Call Alert
- 3.2.2.11 SNSZ Status
- 3.2.2.12 SNSZ Message:
- 3.2.2.13 SNSZ Interconnect:
- 3.3 Radio Inhibit
- 3.4 Setting Squelch
- 3.5 Operating Modes
- 3.1 Basic Operation
- Radio Wide Features
- 4.1 Option Buttons
- 4.2 Menu Mode
- 4.3 Time-Out Timer
- 4.4 Home Channel Select
- 4.5 Power Output Select
- 4.6 Alert Tone Select
- 4.7 Ignition Power Down Duration
- 4.8 Horn Alert
- 4.9 Microphone Off-Hook Detect
- 4.10 Surveillance Mode
- 4.11 Public Address
- 4.12 Scanning
- 4.13 Scan Lists
- 4.14 Over the Air Programming
- 4.15 Over the Internet Programming
- 4.16 Auto / Unmute
- 4.17 Location Services
- 4.18 Emergency Alarm Receive Indicator
- 4.19 Kiosk Mode
- 4.20 Analog Noise Reduction
- Conventional Mode Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit / Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Channel Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF / ANI Signaling
- 5.13 Project 25 Mode Features
- 5.13.1 Digital Unit ID
- 5.13.2 Talkgroup ID
- 5.13.3 Network Access Code (NAC)
- 5.13.4 EFJohnson System Out-of-Range Indicator
- 5.13.5 EFJohnson System Automatic Registration
- 5.13.6 P25 Group Calls
- 5.13.7 P25 Unit Calls
- 5.13.8 P25 Conventional Telephone Calls
- 5.13.9 Call Alert
- 5.13.10 Call History
- 5.13.11 Messaging
- 5.13.12 Status Messaging
- 5.13.13 P25 Packet Data
- 5.14 Keypad Programming
- 5.15 Text Messaging
- SMARTNET / SmartZone / P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Unit Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET / SmartZone / P25 Trunking Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 P25 Radio Unit Monitor
- 6.14 SmartZone and P25 Trunking Unique Features
- 6.14.1 Busy Override
- 6.14.2 Site Trunking
- 6.14.3 Determining Current Site and Searching for a New Site
- 6.14.4 Locking / Unlocking a Site
- 6.14.5 Auto Site Search
- 6.14.6 P25 Wide Area Scan
- 6.14.7 Normal P25 and SmartZone Control Channel Hunt
- 6.14.8 Talkgroup Steering through System Access Permissions
- 6.14.9 Radio Information
- 6.14.10 Current Software version in the radio
- 6.15 P25 Trunking System Single Touch
- 6.16 P25 Messaging
- Secure Communication (Encryption)
- Data Features
- Tones & Error Messages
- Service Information
Draft 02 - Sep 1 2015
5-22 Viking Mobile Radio Operating Manual
Conventional Mode Features
5.13.6.1 Changing Talkgroup Assigned To a Channel
If the Talkgroup Select option switch is programmed, the talkgroup assigned to a channel
can be changed by the user. The operation can also be selected from the menu as Select
TG, or “TGSEL” from the soft button menu (Lightning Control Head only). The new
talkgroup continues to be assigned to the channel until it is manually changed again
(cycling power or selecting another channel does not reselect a default talkgroup). Change
the talkgroup assigned to a channel as follows:
1 Select the channel to be changed and then press the Talkgroup Select option switch.
2 Rotate the Select switch to display the talkgroup to be assigned to that channel.
Talkgroups are indicated by a unique identification in the alphanumeric display.
3 To select that talkgroup and return to normal operation, press the Talkgroup Select
switch again or press the Select switch. A single beep sounds when the Select switch is
pressed (if that option is enabled). If talkgroup selection has been disabled on the
channel by programming, the talkgroup does not change, “NO LIST” is displayed, and
a tone sounds.
5.13.7 P25 Unit Calls
Unit calls (also called Individual Calls) can be placed to a specific radio on Project 25
channels using the Unit Call option switch (if programmed) or by menu selection. Only
the individual ID of the target radio is sent (a talkgroup ID is not sent). The radios that can
be called are preprogrammed in the Unit Call list.
To receive a unit call, the RF channel of the call must be selected or scanned and the
correct NAC and unit ID must be detected. The ID of the calling radio is then transmitted
back. To respond to the call, the radio must be programmed with the Unit Call option
switch, and have a Unit Call programmed with the ID of the calling radio.
5.13.7.1 Place and Receive a Unit Call
To place and receive a Unit Call:
1 To transmit a unit call, press the Unit Call option switch, menu option, or soft button
option (Lightning Control Head only). The alias (tag) of the last Unit Call is displayed.
Direct entry is allowed using the front buttons of the Digital Keypad Mic.
2 If required, rotate the Select switch to display the desired alias/ID. The alias and ID of
the unit calls that have been programmed are alternately displayed.
3 Press and then release the PTT switch. Ringing is then heard and “WAIT” displayed to
indicate that the radio is being rung. To disable this ringing but not the call, briefly
press the PTT switch again. Ringing occurs for 20 seconds or until the call is answered,
whichever occurs first.