User's Manual
Table Of Contents
- Safety Information
- General
- Controls And Display
- General Operation
- Radio Wide Features
- Conventional Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit/Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF/ANI Signaling
- 5.13 Single Tone Encoder
- 5.14 MDC1200 Compatibility
- 5.15 Project 25 Mode Features
- 5.16 Keypad Programming
- SMARTNET/SmartZone/P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Private (Unit-To-Unit) Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET/SmartZone/P25 Trunked Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 SmartZone and P25 Trunking Unique Features
- 6.13.1 Busy Override
- 6.13.2 Site Trunking
- 6.13.3 Determining Current Site and Searching For a New Site
- 6.13.4 Locking/Unlocking a Site
- 6.13.5 ZoneFail Site Lock
- 6.13.6 P25 Wide Area Scan
- 6.13.7 Normal P25 and SmartZone Control Channel Hunt
- 6.13.8 Talkgroup Steering Via System Access Permissions
- 6.13.9 P25 Wide Area Scan
- Miscellaneous
- Determining Available Options
- 5300 ES Mobile Firmware Versions
- Password Description
- Secure Communication (Encryption)
Draft
December 2006 5300 ES Series Mobile Radio Operating Manual -5
Lost Signl - Signal from the infrastructure has been lost during an interconnect call.
Low Power - The current channel is strapped to low power and that the user can not select
high power at this time.
Msg Failed - The current channel is strapped to low power and that the user can not select
high power at this time.
Narrow - The current conventional channel is programmed as a narrow channel.
No Ack - The radio did not receive an ACK for the current signaling attempt.
No Edit - The current list is not able to be edited.
No Encrypt - Encryption is not available for the selected channel.
No List - No list is available for the selected channel.
No Message - No message is programmed for transmission.
No Reply - Radio cloning failed due to no response.
No Service - OTAR service is not available.
No Site - No site with a verified ID is yet on the dynamic site list.
No Keys - No keys are available for the key select function.
Out Of Rng - This error indicates no control channel has been found for trunking
operation.
Parms Fail - The checksum of the profile / user parameters does not match the calculated
checksum. This indicates that there is an error in the parameters file. This message only
occurs if the redundant copy of the parameters is also corrupt or is unable to be used.
Rekey Fail - This error indicates a failure in a rekeying process.
Rx Only - The selected channel is Rx only.
Sts Failed - No acknowledgement was received while sending a status report.
Timeout - A time out has occurred in attempting the current function.
Too Hot - The mobile has passed the TOO HOT temperature threshold. Under these
conditions the radio will not allow Tx.
Tx Timeout - The Tx time-out timer has expired and Tx has been terminated.
VOLTAGE HI - The input voltage to the mobile is too high.