User's Manual
Table Of Contents
- Safety Information
- General
- Controls And Display
- General Operation
- Radio Wide Features
- Conventional Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit/Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF/ANI Signaling
- 5.13 Single Tone Encoder
- 5.14 MDC1200 Compatibility
- 5.15 Project 25 Mode Features
- 5.16 Keypad Programming
- SMARTNET/SmartZone/P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Private (Unit-To-Unit) Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET/SmartZone/P25 Trunked Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 SmartZone and P25 Trunking Unique Features
- 6.13.1 Busy Override
- 6.13.2 Site Trunking
- 6.13.3 Determining Current Site and Searching For a New Site
- 6.13.4 Locking/Unlocking a Site
- 6.13.5 ZoneFail Site Lock
- 6.13.6 P25 Wide Area Scan
- 6.13.7 Normal P25 and SmartZone Control Channel Hunt
- 6.13.8 Talkgroup Steering Via System Access Permissions
- 6.13.9 P25 Wide Area Scan
- Miscellaneous
- Determining Available Options
- 5300 ES Mobile Firmware Versions
- Password Description
- Secure Communication (Encryption)
Draft
December 2006 5300 ES Series Mobile Radio Operating Manual -21
Figure 5.1 5300 ES Keypad Programming Menu Flowchart
5.16.2 Zone Password
Note Make sure that the zone password(s) are not lost because they cannot be overridden in the
field. The PC Configure software must be used to add a new password.
Each zone can be programmed with a password by the PC Configure software to prevent
unauthorized reprogramming of zone by keypad programming. When this password is
programmed, it must be entered before system or channel parameters in that zone can be
changed by keypad programming. The zone password is programmed in the Zones > Edit
Zone screen of the PC Configure programmer. This screen is displayed by clicking the
Edit Zone button. A different password can be programmed for each zone.
When an attempt is made to select a system or channel parameter in a password protected
zone, “PASSWORD” is flashed. The password is always eight digits long and is entered
using the same procedure as used for the power-up password described in
Section 3.2.
After the password is entered, system and channel parameters for that zone can be
reprogrammed normally.
5.16.3 Zone Change Parameter
The “CHNG ZONE” menu parameter selects the zone containing the conventional
channel to be reprogrammed. It does not change the zone selected for normal operation.
Press the Select switch to select the “CHNG ZONE” parameter and then scroll through the
programmed zones by rotating that switch. When the desired zone is displayed, select it by
pressing the Select switch.
Change
Change
Channel
Zone
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx (Time-Out) Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Timer On-Off
Sq Adjust*
Chan Space*
Tlk Grp ID Sel**
* Analog only ** Digital only
Tx Type Sel***
*** Mixed Mode Ch Only
Chan Alias
Strapping
Key Select