Operating Manual Part 15
Table Of Contents
- Safety Information
- General
- Controls And Display
- General Operation
- Radio Wide Features
- Conventional Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit / Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF / ANI Signaling
- 5.13 Project 25 Mode Features
- 5.14 Keypad Programming
- 5.15 Text Messaging
- 5.16 Sending Global Positioning System (GPS) Data
- SMARTNET / SmartZone / P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Private (Unit-To-Unit) Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET / SmartZone / P25 Trunked Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 SmartZone and P25 Trunking Unique Features
- 6.13.1 Busy Override
- 6.13.2 Site Trunking
- 6.13.3 Determining Current Site and Searching for a New Site
- 6.13.4 Locking / Unlocking a Site
- 6.13.5 Auto Site Search
- 6.13.6 ZoneFail Site Lock
- 6.13.7 P25 Wide Area Scan
- 6.13.8 Normal P25 and SmartZone Control Channel Hunt
- 6.13.9 Talkgroup Steering through System Access Permissions
- 6.13.10 P25 Wide Area Scan
- 6.14 P25 Trunking Unique Features
- Miscellaneous
- Determining Available Options
- Password Description
- Secure Communication (Encryption)
- Service Information
October 2008 5300 ES Series Mobile Radio Operating Manual 5-23
Conventional Features
Press the Select switch to select the displayed parameter. A single beep sounds when the
switch is pressed (if that option is enabled). Press the PROG option switch from one of the
main menus to exit keypad programming or from other menus to exit back one level. A
flowchart showing the keypad programming mode menu structure is located Figure 5.1.
Refer to the descriptions which follow for more information.
Figure 5.1 5300 ES Keypad Programming Menu Flowchart
5.14.2 Zone Password
Each zone can be programmed with a password to prevent unauthorized reprogramming
of zone by keypad programming. When this password is programmed, it must be entered
before system or channel parameters in that zone can be changed by keypad programming.
A different password can be programmed for each zone.
Note Make sure that the zone passwords are not lost because they cannot be overridden in the
field. PC Configure must be used to add a new password.
When an attempt is made to select a system or channel parameter in a password protected
zone, “PASSWORD” is flashed. The password is always eight digits long and is entered
using the same procedure as used for the power-up password described in Section 3.2.
After the password is entered, system and channel parameters for that zone can be
reprogrammed normally.
5.14.3 Zone Change Parameter
The “CHNG ZONE” menu parameter selects the zone containing the conventional
channel to be reprogrammed. It does not change the zone selected for normal operation.
Change
Change
Channel
Zone
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx (Time-Out) Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Timer On-Off
Sq Adjust*
Chan Space*
Tlk Grp ID Sel**
* Analog only ** Digital only
Tx Type Sel***
*** Mixed Mode Ch Only
Chan Alias
Strapping
Key Select