Service Manual Part 2
TRANSCEIVER PROGRAMMING
3-25
September 2001
Part No. 001-5100-001
Frequency - The transmit and receive frequency of
the control channel. These are the mobile frequen-
cies, not the repeater frequencies. Only multiples of
5 kHz and 6.25 kHz are valid. With 800 MHz fre-
quencies, a receive frequency 45 MHz above the
transmit frequency is automatically entered.
New Entry Button
- Click this button to display the
dialog box used to add another control channel.
Trunking Call List Screen
This screen is shown above, and it allows the list
of IDs used for private calls to be programmed. A
maximum of 16 IDs can be programmed (see Section
2.7.4).
To edit this list, click the Trunking Call List tab
and then the “Modify List” button on the right side.
This following information is then programmed in the
dialog box that is displayed:
Entry Number
- This box selects the entry to be
edited. The scroll bars to the right of this box select
the desired entry. A phone list can contain up to 16
entries. Selecting a new entry number automatically
validates and stores the current entry. If the current
entry contains an invalid field, the entry number does
not change and the invalid field is highlighted.
Entry Alias
- Up to ten characters can be entered to
identify the user being called. This identification is
displayed when the mobile to be called is selected by
the user from the list. Only uppercase letters can be
entered, so lowercase letters are automatically con-
verted to uppercase by the program.
Call ID
- This is the ID of the radio being called.
Valid entries are 1-49152. A “0” is detected as no
entry.
Close Button
- Verifies the current entry, stores it,
and then closes the dialog box. If the current entry
contains an invalid field, the dialog box does not
close and the invalid field is highlighted.
Priority Monitor Scan Screen
This screen is shown above, and it programs up to
three Priority Monitor scan lists that are allowed. Each
scan list can contain up to 15 channels plus a priority
channel (see Section 2.7.12). These channels must be
from the same SMARTNET/SmartZone system. Chan-
nels set up for other systems are not allowed.
To edit a list, click the Priority Monitor Scan tab
and then click the “Modify List” button on the right
side. A screen similar to the top screen shown above is
then displayed to select the channels to be included in
that scan list. Select channels as follows:
1. Select the scan list to be edited using the scroll bars
next to the “Scan List To Modify” box.
2. Select the first zone with channels to be included
and select the desired channels. Repeat for the other
zones.