Operating Manual
5-24 5100 ES Models II/III Portable Radio Operating Manual March 2008
Conventional Mode Features
Keypad programming allows conventional channel parameters such as the transmit and
receive frequency, Call Guard squelch code, and encryption key to be changed. In
addition, several conventional mode timers can be changed. It cannot be used to reprogram
disabled channels or any SMARTNET/SmartZone/P25 Trunked information.
Figure 5.1 Keypad Programming Menu Flowchart
5.15.1 Menu Description
A menu system is used to select parameters in the keypad programming mode. A
flowchart showing the keypad programming mode menu structure is located in Figure 5.1.
When the keypad programming mode is selected by the Keypad Programming option
switch or menu parameter, the first menu parameter “Chng Zone” is displayed as just
described. Press the Up/Down switch to scroll through the available parameters which are
as follows.
• CHNG ZONE
• CHNG CHAN
•SYS PARMS
• CHAN PARMS
Zone
Channel
Change
Change
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Tmr On-Off
Squelch Adj*
Chan Spacing*
<F1> = Exit/Back
<F2> = Select
Up/Down = Scroll
Talk Grp ID**
* Analog Only
** Digital Only
Tx Type Sel***
*** Mixed Mode Ch Only
Key Select
Strapping
Chan Alias