User's Manual
-- TX VSWR - Voltage Standing Wave Ratio. This is the ratio of the
forward power sensor to the reflected power sensor given that both
measurements exceed the minimum measurement. The minimum
measurement is defaulted to 0.9 volts. If either of the sensors is below the
minimum measurement, the resulting sensor measurement will be 2.001.
-- TX Fan Op - Fan Operating sensor in volts.
-- TX Fan1 Cur - Fan Current sensor 1 in volts.
-- TX Fan2 Cur - Fan current sensor 2 in volts.
--
--
[TOP]
>> [BACK]
[BACK]
--> RX -Receiver menu
>> RX Tests - Test the receiver. Use the Rx Config menu to configure the receiver
test.
-- BER [START/STOP] Bit Error Rate Test. Results displayed in%.
-- RSSI [START/STOP] Receive Signal Strength (relative). Results
displayed in%. Not all RF decks support this feature.
--
--
[TOP]
>> RX Config - Configure the RX Tests.
[BACK]
-- RX Min Freq MHz - Display minimum tuned RX frequency.
-- RX Max Freq MHz - Display maximum tuned RX frequency.
-- RX Freq - Review/Edit RX Frequency. This frequency is applicable for
Rx Tests. By default, the center of the tuned frequency range is used.
--
--
[TOP]
>> RX Monitors - Shows the result of a receiver monitor. See Monitors/Faults for
more detail.
[BACK]
-- RX Synth Lock - Receiver synthesizer. The measurement is FALSE
when locked, TRUE when not locked.
--
--
[TOP]
>> [BACK]
[BACK]
--> Power Supply
>> PS Tests - Test the power supply.
-- PS Oput [START/STOP] -Displays the primary output of the power
supply in volts.
--
--
[TOP]
[BACK]