User's Manual
• Hi Dev Amp Hz -Configure the amplitude for the “Analog High Dev” waveform.
• [TOP]
• [BACK]
-- Test Duration -Set the Tx Test duration.
• Timed (sec) -Set the Tx Test duration in seconds. Only applicable when Tx Test is
started as “Timed”
• Cycled - Set the Tx Test duration in number of Tx cycles, where a Tx cycle
includes a duration of time where the transmitter is keyed, followed by a duration of
time where the transmitter is dekeyed.
•• Test Key Time - Number of seconds to keep PA keyed
•• Test Dekey Time - Number of seconds to keep PA dekeyed
•• Test Cycles - number of iterations
••
••
[TOP]
• [TOP]
[BACK]
• [BACK]
--
>> TX Monitors - Shows the result of a transmitter monitor. See Monitors/Faults
for more detail. For many of the monitors, the transmitter must be in the keyed
state as a result of actions under the Tx Control, or the Tx Tests menu items.
[BACK]
-- TX Synth Lock - Transmit synthesizer. The measurement is FALSE
when locked, TRUE when not locked.
-- TX Temperature - Temperature of the PA in degrees C. This monitor
checks that the PA does not get too hot.
-- TX Fwd Power - Output of forward power sensor in volts when keyed.
This monitor checks for a minimum level of forward power when the
transmitter is keyed.
-- TX NoFwd Power - Output of forward power sensor in volts when
dekeyed. This monitor checks that power is not radiated when not keyed.
-- TX Power1 - Output of Exciter current sensor. Not applicable in all
models.
-- TX Power2 - Output of Exciter current sensor. Not applicable in all
models.
-- TX Power3 - Output of Exciter current sensor. Not applicable in all
models.
-- TX Power4 - Output of Exciter current sensor. Not applicable in all
models.
-- TX Imbal ½ - Ratio of Tx Power1 to Tx Power2 or Tx Power2 to Tx
Power1. Number will always be greater than 1. Not applicable in all
models.
-- TX Imbal ¾ - Ratio of Tx Power3 to Tx Power4 or Tx Power4 to Tx
Power3. Number will always be greater than 1. Not applicable in all
models.