2. RDM Site - Connect the MED box to the Signal
Source as described in the MED box operation and
service manual. Set the MED box parameters to the
desired system (choose a Group ID that is not cur-
rently active by other system users).
3. RDM Site - Connect the Signal Source to the Signal
Analyzer (monitor function for a communications
service monitor). Adjust the output level of the Sig-
nal Source to the required input level of the Signal
Analyzer. Enable the internal modulation source
and set the modulation frequency to 1 kHz at
1.5 kHz deviation (800 Hz for 900 MHz) and verify
with the Signal Analyzer that the deviation is
correct.
4. RDM Site - Disable the internal modulation source
without changing the deviation setting. Enable the
external modulation port. Adjust the MED box to
encode the Multi-Net data. Adjust the data out level
of the MED box to achieve 1 kHz (800 Hz for
900 MHz) of deviation as measured on the Signal
Analyzer.
5. RDM Site - Enable the internal modulation source
with a 1 kHz tone. The composite deviation will
now measure 2.5 kHz (1.6 kHz for 900 MHz) on the
Signal Analyzer.
NOTE: 800 MHz systems - 1 kHz Low Speed Data and
1.5 kHz for the 1 kHz tone. 900 MHz systems - 800 Hz
Low Speed Data and 800 Hz for the 1 kHz tone.
6. RDM Site - Adjust the Signal Source to 100 ยตV of
RF level. Connect the Signal Source to the RDM
antenna port.
7. RDM Site - A dispatch call should now be set up. If
not, check the MED box to be sure that the Multi-
Net data is being encoded and the correct Multi-Net
parameters are being sent.
8. Transmitter Site - Record the deviation of the
transmitted signal (it should be 2.5 kHz for 800
MHz systems and 1.6 kHz for 900 MHz systems).
9. RDM Site - Disable the 1 kHz tone on the internal
modulation source of the Signal Source (the external
port must remain active). The dispatch call should
still be complete.
10.Transmitter Site - At the transmit site record the
deviation of the transmitted signal (it should be
1 kHz of Low Speed Data for 800 MHz and 800 Hz
of Low Speed Data for 900 MHz systems). If the
deviation is not correct, adjust the level to the cor-
rect setting as described in the repeater service
manual.
11. RDM Site - Enable the 1 kHz tone on the internal
modulation source of the Signal Source (the external
port must remain active). The dispatch call should
still be complete.
12.Transmitter Site - At the transmit site record the
deviation of the transmitted signal (it should be
2.5 kHz for 800 MHz systems and 1.6 kHz for
900 MHz systems). If the deviation is not correct,
adjust U44 in the RVM (see Step 10) to attain
2.5 kHz deviation for 800 MHz systems and
1.6 kHz deviation for 900 MHz systems. Refer to
NOTE 2 on page 1-11.
13.Voter Site - On the MLM drawer connect a Trans-
mitter Test Set to W6 of J701 and record this meter
reading for Voice Level from Switch alignment.
(Voice Level _____________)
1.3.4 VOICE LEVEL TO SWITCH ALIGNMENT
1. Set S2 switches in the MLM drawers as shown in
Figure 1-17 and reset the MLM. This enables the
Receive Audio Gate and Logic Squelch Gate.
Figure 1-17 MLM S2 GATE SETTINGS
2. On the MLM drawer connect a Transmission Test
Set to TP2 and adjust R202 for a meter reading of
-12 dBm. (See Figure 1-23.)
O
N
2
1
8
7
6
5
4
3
S
2
L
S
B
M
S
B