Service manual

INTRODUCTION
1-7
March 2000
Part No. 001-3139-502
1.3 VOTER SYSTEM ALIGNMENT
Note: See Section 3.11 for 2000 RDM alignment.
1.3.1 PRELIMINARY
1. Verify that S3, section 5 in the MLM is set for the
proper mode (see Figure 1-23). For a Voter system
the switch should be “up” or “On” indicating Voter
Mode. For a Non-Voter system, the switch should
be “down” or “Off” indicating Non-Voter Mode.
Figure 1-7 MLM S3 SWITCH SETTINGS
2. Record the settings of S9 in the MLM drawer.
1 ______ 2 ______ 3 ______ 4 ______
Figure 1-8 MLM S9 SWITCH
3. Put S9 into Test Mode by setting the switch as
shown in Figure 1-9. Reset switch S8 (see Figure
1-23) which must be pressed after changing the
switches to actually enter the selected mode.
Figure 1-9 MLM S9 TEST MODE
4. Record the settings of S2 in the MLM drawer.
1 _____ 2 _____ 3 _____ 4 _____
5 _____ 6 _____ 7 _____ 8 _____
Figure 1-10 MLM S2 SWITCH
5. Set the MLM drawer S2 switches as shown in Fig-
ure 1-11. This enables the repeat gate, logic squelch
gate and the transmitter.
Figure 1-11 MLM S2 SWITCH SETTING
NOTE: Either of the following two procedures can be
used to setup the RDM and RVM alignment. Procedure
1 may not work in some systems due to specific instal-
lation issues. Procedure 2 will provide repeatable and
consistent results when using properly calibrated test
equipment and is the preferred
procedure.
NOTE: Refer to Simulcast System Alignment manual
(Part No. 004-0690-300) for the alignment procedure
in a Simulcast System.
O
N
2
1
8
7
6
5
4
3
S
3
V
O
T
E
R
M
O
D
E
=
O
N
L
S
B
M
S
B
O
N
S9
2
1
4
3
O
N
S9
2
1
4
3
MSB
LSB
O
N
2
1
8
7
6
5
4
3
S
2
L
S
B
M
S
B
O
N
2
1
8
7
6
5
4
3
S
2
L
S
B
M
S
B