Datasheet

176
EE741
v1.0 / Modification rights reserved
Scope of supply
EE741:
• EE741 according to ordering guide
• 1 x Allen key
• 1 x USB cable
• Operating instructions
• Inspection certificate according to DIN EN10204 - 3.1
Gauge mounting block:
• Gauge mounting block incl. mounted sealing plug
Accessories
- Inlet and outlet path BSP thread, stainless steel, for mounting block DN15 HA070215
DN20 HA070220
DN25 HA070225
Dimensions (mm/inch)
Mounting
block
Thread
R
p
or NPT
DN15 1/2"
DN20 3/4"
DN25 1"
Internal thread:
Whitworth thread according to EN 10226
(old DIN 2999) or NPT
M12 x 1
53,5
2.11“
85
3.35“
100
3.94“
50
1.97“
Connection diagram
Display (optional)
Analogue/switch/
pulse output
1...V+
2...Output 1
3...GND
4...Output 2
Modbus RTU
1...V+
2...RS485 A (=D+)
3...GND
4...RS485 B (=D-)
M-Bus / Meter-bus
1...V+
2...M-Bus
3...GND
4...M-Bus
1 2
34
M12 plug on device
The output signal is freely selectable and scalable by the user:
Output 1: Analogue [mA] or switch
Output 2: Pulse or switch
The state-of-the-art LCD shows the current measured values and
the overall consumption. The user specific device setup can be
easily performed with the push buttons and intuitive menu guidance.
The display can be rotated in 90° increments with a push button for
convenient orientation in any mounting position of the flow meter.
The EE741 without display can be configured by the user via USB
interface with the free EE-PCS product configuration software.