Datasheet
v1.2 / Modification rights reserved
EE800
50
Ordering Guide
Order Example
EE800-M12A3MC52SCL-10SCH10
Model: CO
2
+ T + RH
CO
2
Range: 0 - 2000 ppm
Output: 0-10 V
Housing design & EU - Standard
colour: RAL9003 / RAL7035
Output 2 Temperature: T (°C)
Temperature Scale: 0...50
Output 3: Dew Point (°C)
Dew Point Scale: -10...10
EE800-M11A3CH74
Model: CO
2
+ T
CO
2
Range: 0 - 2000 ppm
Output: 0-10 V
Housing design & EU - Grey
colour: RAL7016
Output 2 Temperature: T (°C)
Temperature Scale: 0...50
EE800-M12HR5000J3RG2D1P3BD8PY2BT2U2
Model: CO
2
+ T + RH
CO
2
Range: 0 - 5000 ppm
Digital output: RS485
Housing design & US
colour: RAL9003 / RAL7035
Display: yes
Protocol: BACnet
Baud rate: 57600
Parity: even
Stopbit: 2
Unit: non-metric
EE800
Hardware Configuration
Model
CO
2
+ T M11
CO
2
+ T + RH M12
CO
2
Range
0 - 2000 ppm no code
0 - 5000 ppm HR5000
Output
0-5 V A2
0-10 V A3
4-20 mA
1)
A6
RS485 J3
T-Sensor passive
2)
none no code
Pt100A TP1
Pt1000A TP3
NTC 10k TP5
Ni1000 Tk6180 TP9
Housing design & colour
EU - Standard (RAL 9003 / RAL 7035) no code
EU - Grey (RAL 7016) CH74
EU - Silver (RAL 9006) CH93
US (RAL 9003 / RAL 7035) RG2
Display
none no code
yes D1
Setup - Analogue outputs
Output 1 CO
2
Scaling according to selected "CO
2
Range" as above
Output 2 Temperature
T (°C) no code
T (°F) MB2
Scale 2 low
0 no code
value
3)
SBL value
Scale 2 high
50 no code
value
3)
SBH value
Output 3 Measurands
Relative Humidity (% RH) MC10
Dew Point (°C) MC52
Dew Point (°F) MC53
none no code
Scale 3 low
0 no code
value
3)
SCL value
Scale 3 high
100 no code
value
3)
SCH value
Setup - Digital output
Protocol
Modbus RTU
4)
no code
BACnet MS/TP
5)
P3
Baud rate
9600 no code
19200 BD6
38400 BD7
57600
6)
BD8
76800
6)
BD9
Parity (Modbus)
no parity PY0
odd no code
even PY2
Stopbit (Modbus)
1 stopbit no code
2 stopbits BT2
Unit
metric-SI no code
non-metric U2
1) not with M12
2) not with J3 / T-Sensor details see www.epluse.com/R-T_Characteristics
3) Within working range. For scaling beyond working range limits please contact the E+E sales representative.
4) Modbus Map and setup instructions: See User Guide and Modbus Application Note at www.epluse.com/EE800
5) Product Implementation Conformance Statement (PICS) availbale at
www.epluse.com/EE800
6) Only for BACnet