Datasheet
4
The highly accurate EE33 series are designed for fast and reliable
measurement of relative humidity / dew point temperature / absolute
humidity / ...under the most demanding conditions.
Neither condensation nor heavy chemical pollutions will affect prompt and
reliable measurements. Process pressures as high as 100 bar (1450 psi) and
continuous high humidity are also no problem for the EE33 series.
The core of the EE33 series is the new monolithic measurement cell type
HMC1, manufactured in thin-film technology by E+E Elektronik.
Chemical contamination and also condensation will actually evaporate due to
the innovative design of the HMC1 measurement cell. The monolithic
construction of the sensor allows a fast return to normal conditions and a
continuation of the measurement.
Additionally, with the inimitable E+E sensor coating the HMC1 measurement
cell is even better protected against corrosive and short-circuit-causing
conductive soils.
Distinctive models and mounting versions allow the EE33 series to be
utilized in numerous applications:
- Measurement of relative humidity during temporary condensation:
the measurement cell is briefly heated, but very intense
- Measurement of dew point temperature at continuous high humidity:
the measurement cell is controlled and heated continuously
- Measurement of relative humidity at continuous high humidity:
the measurement cell is controlled and heated continuously;
an additional temperature sensor is added
- Measurement of relative humidity at high chemical exposure and
average humidity:
the measurement cell is briefly heated, but very intense
- Measurement of relative humidity at process pressure up to 100bar (1450psi)
and average humidity:
the measurement cell is installed in a special high pressure probe
The configuration software included in the scope of supply allows user friendly
setup of the operation / sensor heating mode as well as selection and adjustment
of the electrical outputs.
EE33
Humidity / Temperature Transmitter for
High Humidity and Chemical Applications
EE33-MFTC
EE33-MFTD
EE33-MFTK
EE33-MFTE
EE33-MFTI
EE33-MFTJ
heated, monolithic
measurement cell
Model Environmental Conditions
C - remote sensing probe up to 120°C (248°F) chemical pollution, temporary condensation
D - remote sensing probe up to 180°C (356°F) chemical pollution, temporary condensation
E - remote sensing probe, pressure tight up to 20bar (300psi) chemical pollution, temporary condensation
I - remote sensing probe, pressure tight up to 100bar (1450psi) chemical pollution, temporary condensation
J - 2 remote sensing probes (RH-measurement), continuous high humidity and condensation
pressure tight up to 20bar (300psi)
K - remote sensing probe (Td-measurement) continuous high humidity and condensation
pressure tight up to 20bar (300psi)
pharmaceutical and food industry
dryers for ceramics, wood, concrete, polyester, etc
mushroom farms
high-humidity storage rooms
climate, test and curing chambers
meteorology
heated, monolithic measurement cell
working range 0...100% RH / -40...+180°C
(-40...356°F)
measurement near condensation
fast recovery after condensation
chemical purge after chemical exposure
pressure tight up to 100bar
(1450psi)
calculation of additional physical quantities
optional sensor coating
Typical Applications
Features
EE33