Datasheet

32
Sensing probe
refer to data sheet of respective sensing probe
Outputs
0...100% RH/ xx...yy°C
2)
0 - 1V -0.5mA < I
L
< 0.5mA
(temperature output scale according to 0 - 10V -1mA < I
L
< 1mA
Txx ordering code) 4 - 20mA (two wire) R
L
< 500 Ohm
Temperature dependence of
analogue outputs max. 0.2 resp. 1
General
Supply voltage
for 0 - 1V output 10 - 35V DC or 9 - 29V AC
for 0 - 10V output 15 - 35V DC or 15 - 29V AC
for 4 - 20mA output 10 - 35V DC
Load resistor for 4 - 20mA output R
L
< []
Current consumption typ. 10mA for DC supply typ. 20mA
eff
for AC supply
Electrical connection screw terminals max. 2.5mm
2
Cable gland M16x1.5 cable Ø 4.5 - 10 mm (0.18 - 0.39”)
(optional connector; type: Lumberg, RSF 50/11)
Material PC or Al Si 9 Cu 3
Protection class of housing IP65; Nema 4
Electromagnetic compatibility EN61326-1 EN61326-2-3 ICES-003 ClassB
Industrial Environment FCC Part15 ClassB
Working temperature range of electronics -40...60°C
(-40...140°F)
Storage temperature range -40...60°C
(-40...140°F)
1) Refer to ordering guide
Technical Data
Connection Diagram
EE220- x1x
- x3x
mV
°C
µA
°C
U
v
- 10V
0.02 A
EE220
EE220- x6x
Humidity/Temperature Probes
Overview of Sensing Probes
Application Picture Measuring Range Accuracy Order Code
RH/T probe for standard applications 0...100% RH ±2% RH (0...90% RH) EE07-PFT1
±3% RH (90...100% RH)
-40...80°C (-40...17F) ±0.1°C (±0.1F) at 20°C (6F)
RH/T probe for clean room applications, 0...100% RH ±2% RH (0...90% RH) EE07-MFT9
food and pharmaceutical industry ±3% RH (90...100% RH)
-40...80°C (-40...17F) ±0.1°C (±0.1F) at 20°C (6F)
RH/T module for installation in small 0...95% RH ±3% RH (10...100% RH) EE03-FT9
spaces or unobtrusive mounting at 21°C (69.F)
-40...85°C (-40...18F) ±0.3°C (±0.5F) at 20°C (68°F)
Temperature Probes
T probe for standard applications -40...80°C
(-40...17F) ±0.1°C (±0.1F) at 20°C (6F) EE07-PT1
T probe for clean room applications, -40...80°C
(-40...17F) ±0.1°C (±0.1F) at 20°C (6F) EE07-MT
food and pharmaceutical industry