EE210
v1.7 / Modification rights reserved
EE210-HT3xPAxB-UwTx005M
Model: Humidity+Temperature Transmitter
Analog output: 0-10V
Housing: standard
Type: wall mount
Display: none
Filter: membrane
Output scaling 1: relative humidity
Scaling 1: 0...100% RH
Output scaling 2: temperature
Scaling 2: 0...100°C
Unit: metric
EE210-HT6xPCx-UwTx005M
Model: Humidity+Temperature Basic Device
Analog output: 4-20mA
Housing: standard
Type: remote probe (Pos. 2)
Display: none
Output scaling 1: relative humidity
Scaling 1: 0...100% RH
Output scaling 2: temperature
Scaling 2: 0...100°C
Unit: metric
EE210P-HTCB
Model: Humidity+Temperature Probe
Cable length: 1.5 m
Filter: membrane
Order Examples
Ordering Guide
MODEL ANALOGUE
1)
DIGITAL
1)
HOUSING TYPE DISPLAY
3)
FILTER (Type A and B)
humidity + temperature (HT) 0-5V (2) RS485 (3) standard (P) wall mount (A) display (D) membrane (B)
0-10V (3) none (x) duct mount (B) none (x) stainless steel sintered (D)
4-20mA (6) remote probe (C)
2)
none (x)
EE210-
MODEL CABLE LENGTH FILTER
humidity + temperature (HT) 1.5 m (C) membrane (B)
3 m (E) stainless steel sintered (D)
EE210P
Accessories
OUTPUT 1 SCALING 1
5)
OUTPUT 2 SCALING 2
5)
UNIT
relative humidity
4)
(Uw) -40...60 (002) relative humidity
4)
(Uw) -40...60 (002) metric (M)
temperature (Tx) -10...50 (003) temperature (Tx) -10...50 (003) non-metric (N)
dew point temperature (TD) 0...50 (004) dew point temperature (TD) 0...50 (004)
frost point temperature (TF) 0...100 (005) frost point temperature (TF) 0...100 (005)
water vapour partial pressure
4)
(Ex) 32...122 (076) water vapour partial pressure
4)
(Ex) 32...122 (076)
mixing ratio
4)
(Rx) -40...140 (084) mixing ratio
4)
(Rx) -40...140 (084)
absolute humidity
4)
(DV) absolute humidity
4)
(DV)
specific enthalpy
4)
(Hx) specific enthalpy
4)
(Hx)
relative humidity 0...100% RH
water vapour partial pressure 0...200mbar 0...3psi
mixing ratio 0...425g/kg 0...2900gr/lb
absolute humidity 0...150g/m³ 0...60gr/ft³
specific enthalpy 0...400kJ/kg 0...200BTU/lb
4) Factory Scaling
5) For Tx, TD und TF;
other scaling upon request
3) Factory setup:
For analogue output versions the display shows the
measurands selected for output 1 and output 2.
For digital output versions the display shows RH and T.
6) Modbus Map and setup instructions:
See User Guide and Modbus Application Note at www.epluse.com/EE210
1) a combination of analog and digital version is not possible 2) The EE210P probe has to be ordered as seperate position; available for 4-20mA and RS485 versions
Type A and B
Type C
Product configuration adapter see data sheet EE-PCA
Product configuration software EE-PCS (free download: www.epluse.com/EE210)
Power supply adapter V03 (see data sheet Accessories)
Remote probe for EE210 Type C:
Position 1:
Position 2:
Analogue outputs setup
PROTOCOL BAUDRATE PARITY STOPBITS UNIT
modbus (1) 9600 (A) odd (O) 1 stopbit (1) metric (M)
19200 (B) even (E) 2 stopbit (2) non-metric (N)
38400 (C) no parity (N)
Digital output setup
6)