Data Sheet

13
www.epluse.comv1.3 / Modification rights reserved
HTE501
6 Sensor Communication
6.1 Command Overview
COMMAND DESCRIPTION
0x2C1B Measurement, single shot, I
2
C clock stretching enabled; Use current resolution
0x241D Measurement, single shot, I
2
C clock stretching disabled; Use current resolution
0x201E Measurement, periodic; Use current resolution and interval
0xE000 Fetch periodic measurement data
0xE016 Fetch dew-point value
0x30A2 Soft Reset
0x3093 Break (end periodic measurement)
0x306D Heater ON
0x3066 Heater OFF
0x3041 Clear Status Register 1
0xF32D Readout of Status Register 1
0xF352 Readout of Status Register 2
0x7029 Read Identification
0x72A7 Read / Write Sensor Settings (RAM)
0x06 I
2
C Reset at general call address 0x0
Table 11: HTE501 commands
6.2 Measured Data Format
Temperature [°C] = (Temperature MSB x 256 + Temperature LSB) /100
Humidity [%RH] = (Humidity MSB x 256 + Humidity LSB) /100
Dew point temp. [°C] = (Dew point MSB x 256 + Dew point LSB) /100
6.3 Measurement Modes
There are two different operation modes to communicate with the sensor:
1. Single Shot Measurement
G:\Produkte\HTEx01\501\Archive\PWRup_HIpin_Modi
Singelshotmode
Periodicmode
IDLEMODE PERIODICMODE IDLEMODE
time
time
COMMANDSingle
ShotMeasurement
Measurement
COMMANDSingle
ShotMeasurement
Measurement
SingleMeasurement
at
p
oweru
p
t
MEAS
V
DD
3.3V
V
PORP
0V
t
PWRU
t
MEAS
t
PWRU
SingleMeasurement
at
p
oweru
p
COMMAND
PeriodicMode
V
DD
3.3V
V
PORP
0V
COMMAND
Break
t
MEAS
t
MEAS
COMMAND
FetchMeasurement
Measurement
t
MEAS
COMMAND
FetchMeasurement
Timedependonmeasurement
intervall,1satstartup
Timedependonmeasurement
intervall,1satstartup
optionalCOMMAND
FetchMeasurement
optionalCOMMAND
FetchMeasurement
IDLEMODE
Timeuntil
nextCOMMAND
Timeuntil
nextCOMMAND
t
MEAS
t
MEAS
READMeasurement
READMeasurement
Measurement
COMMAND
FetchMeasurement
Measurement
Timedepend
onCOMMAND
19.10.2021
Figure 8: Single shot measurement