FCC ID: SIWHP5195A
NAME OF TEST: RADIATION INTERFERENCE
RULES PART NUMBER: 15.249, 15.209
REQUIREMENTS:
FIELD STRENGTH of
Fundamental:
FIELD STRENGTH
of Harmonics
S15.209
902-928 MHZ
2.4-2.4835 GHz
94 dBuV/m @3m
54 dBuV/m @3m
30 -88 MHz 40 dBuV/m @3M
88 - 216 MHz 43.5
216 - 960 MHz 46
ABOVE 960 MHz 54 dBuV/m
EMISSIONS RADIATED OUTSIDE OF THE SPECIFIED FREQUENCY BANDS, EXCEPT FOR HARMONICS,
SHALL BE ATTENUATED BY AT LEAST 50 dB BELOW THE LEVEL OF THE FUNDAMENTAL OR TO THE
GENERAL RADIATED EMISSION LIMITS IN 15.209, WHICHEVER IS THE LESSER ATTENUATION.
Continued:
Frequency (MHz) Antenna Polarization Emission Level (dBuV/m) FCC 15 Subpart C Limit
(dBuV/m)
High frequency(2470.0 MHz)
137.30 Vertical 30.50 43.5
2470.00 Vertical 82.15 94.0
4940.10 Vertical 31.56 54.0
7410.20 Vertical 32.30 54.0
12350.20 Vertical 31.45 54.0
136. 90 Horizontal 32.15 43.5
2470.00 Horizontal 81.86 94.0
4940.10 Horizontal 31.31 54.0
7410.20 Horizontal 32.10 54.0
12350.20 Horizontal 32.05 54.0
TEST PROCEDURE: ANSI Standard C63.4-2003 using a ANRITSU spectrum analyzer with a
pre-selector and an appropriate antenna. The resolution bandwidth of spectrum
analyzer was 100 kHz below 1 GHz and 1 MHz above 1 GHz. An appropriate sweep speed
was used. When an emission was found, the table was rotated to produce the maximum
signal strength. The antenna was placed in both the horizontal and vertical planes
and the worse case emissions were reported. The spectrum was searched to at least
the tenth (10) harmonic of the fundamental.