Revised date : 14-November-2019
In case of fire, use CO
2
, dry chemical powder extinguishers.
Since irritant and corrosive gas may be produced by battery pack on fire, use self-
contained breathing apparatus while extinguishing fire when danger is predicted.
Move batteries to a safer place immediately if a fire breaks out nearby. Use a large
amount of water as a supportive measure to cool the exterior of batteries if exposed to
fire to prevent rupture
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
In the unlikely event that liquid leaks from the battery, Wear personal protective
equipment (Safety gloves, goggles and gas mask for organic gases). Avoid skin contact.
6.2. Environmental precautions
Dispose of damaged battery pack in accordance with federal, state and local
regulations.
Cover battery pack terminals to prevent accidental short-circuit when batteries are
mixed.
6.3. Methods and material for containment and cleaning up
Use absorbent material (sand, vermiculite, etc.) to absorb any exuded material. Seal
leaking battery (unless hot) and contaminated absorbent in a plastic bag and dispose of
in accordance with local regulations.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Do not disassemble, open, remodel, or solder. Do not short + and – terminals with
metal.
Charge with a Dyson charger designed for use with this battery pack.
The battery may present a risk of fire or burns if mistreated. Do not disassemble, crush,
short contacts, heat above 140°F (100°C), or incinerate. Do not use pack if damaged.
7.2. Conditions for safe storage, including any incompatibilities
Store at < 45°C. Avoid overheating, e.g. through incident solar radiation or radiant heat
source. Do not expose to water or condensation.