Installation Guide

SV-COM-760, SV-COM-T25 and SV-COM-T83 Installation and Configuration
SkyView System Installation Guide Revision AK (draft) 16-13
On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
Shielded cable between transceiver module #1 Pins 23 and 9, and SV-INTERCOM-2S Pins 1 and
25:
This cable consists of two wires plus shield.
Use one of the wires to connect transceiver module #1 Pin 23 to SV-INTERCOM-2S Pin
25.
Use the other wire to connect transceiver module #1 Pin 9 to SV-INTERCOM-2S Pin 1
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
On the transceiver module #1 end, continue the shield as far into the connector as
possible until you're forced to pare it back to access the two inner wires. Put some heat
shrink tubing over the shield to keep it electrically isolated - the shield at the
transceiver module #1 end of this cable is not electrically connected at transceiver
module #1.
On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
Shielded cable between transceiver module #2 Pins 1 and 2, and SV-INTERCOM-2S Pins 1 and 7:
This cable consists of two wires plus shield.
Use one of the wires to connect transceiver module #2 Pin 2 to SV-INTERCOM-2S Pin 7.
Use the other wire to connect transceiver module #2 Pin 1 to SV-INTERCOM-2S Pin 1
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
On the transceiver module #2 end, continue the shield as far into the connector as
possible until you're forced to pare it back to access the two inner wires. Put some heat
shrink tubing over the shield to keep it electrically isolated - the shield at the
transceiver module #2 end of this cable is not electrically connected at transceiver
module #2.
On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
Shielded cable between transceiver module #2 Pins 23 and 9, and SV-INTERCOM-2S Pins 1 and
15:
This cable consists of two wires plus shield.
Use one of the wires to connect transceiver module #2 Pin 23 to SV-INTERCOM-2S Pin
15.
Use the other wire to connect transceiver module #2 Pin 9 to SV-INTERCOM-2S Pin 1
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
On the transceiver module #2 end, continue the shield as far into the connector as
possible until you're forced to pare it back to access the two inner wires. Put some heat
shrink tubing over the shield to keep it electrically isolated - the shield at the