System Planning
SkyView System Installation Guide Revision S 2-9
dynamic magnetic fields (e.g., AC currents, non-constant DC currents, and non-stationary
ferrous material such as electric turn coordinators and control surfaces). Thus, you must avoid
mounting the module close to sources of dynamic magnetic fields, avoid wires that carry large
amounts of current, and use non-magnetic fasteners for installation (see caution below).
Dynon’s general rule of thumb is that 1 to 2 feet between the module and sources of magnetic
fields is generally good enough, but 2 or more feet is better.
Figure 2 ADAHRS Installation Orientation
An ADAHRS module should be mounted within one degree of parallel to all three aircraft axes,
with the pneumatic fittings facing toward the front of the aircraft. The module’s mounting tabs