Installation Guide User Manual

SV-EMS-220/221 Installation and Configuration
7-62 SkyView System Installation Guide - Revision S
When OIL TEMP is > 190° F, the OIL TEMP gauge will display different ranges:
100-120 and 230-266° F in YELLOW
120-230° F in GREEN
266-280° F in RED
The alarm type for oil temperature is the “self-clearing” type.
EMS Sensor Definitions, Mapping, and Settings
EMS Sensor Definitions
All EMS sensor installations require a SkyView Sensor Definitions file. This file provides
characterizations of all sensors that SkyView supports, and is occasionally updated to add
additional supported sensors and correct issues with existing sensors. The most current version
of the SkyView Sensor Definitions file is preloaded onto each display prior to shipment. The
most current version of the SkyView Sensor Definitions file can be downloaded from
http://downloads.dynonavionics.com. If you have more than one SkyView display, and the
SkyView Sensor Definitions file on each display is different from one another, a warning
message will be displayed:
EMS SFG FILE MISMATCH.
If you need to update the SkyView Sensor Definitions file, download the file and use the
instructions found in the How to Load and Delete Files Section.
EMS Sensor Input Mapping
If your engine installation is listed in the Example Engine Sensor and Transducer Installations
Section, we recommend you install one of the sensor mapping and settings files onto the