Installation Guide Instruction Manual

EMS Configuration
Voltage
The voltmeter info item reports the voltage that the FlightDEK-D180 reads on its Master Power
input (pin 1 on the EFIS 25-pin connector). Because of this, there is no sensor to install or
configure. Simply, select the alarm mode and the analog bar thresholds as described in Alarm
and Color T
hreshold Configuration on page 6-2. Configure the voltmeter inf
o bar to display in
the desired location(s), as described in the FlightDEK-D180 Pilot’s User Guide > Global
Configuration Settings > Info Item Configuration
section.
Current
If a current sensor has been installed, set the DISPLAY
parameter to ON, otherwise, set it to OFF. First, select
whether your ammeter will be showing positive and
negative currents (-60A TO 60A; used for Location A)
or only positive currents (0A TO 60A; used for
Locations B and C). This will depend on your
installation as mentioned in the Ammeter
Shunt installation section on page 3-12. Select
the alarm
mode and the analog bar thresholds
as described in Alarm and Color Threshold
Configuration on page 6-2. Change the
SENSOR TYPE to the correct num
ber using
the sensor type table. Configure the ammeter
info bar to display in the desired location(s),
as described in the FlightDEK-D180 Pilot’s
User Guide > Global Configuration Settings >
Info Item Configuration
section.
Sensor
Type
Ammeter Sensor
1 Dynon P/N 100412-000
2 GRT CS-01
If you are using the GRT CS-01 Hall effect sensor, you m
ay need to set the zero-point of the
sensor. After you have selected a SENSOR TYPE of “2,” the OFFSET parameter will be
displayed. Adjust the OFFSET (in increments of 1 amp) until the current displayed on the EMS
Main page screen is correct at a known current.
FlightDEK-D180 Installation Guide 6-15