Installation Guide Owner manual

EMS Configuration
General Purpose Thermocouple
Select the alarm mode as described in the Alarm and
Color Threshold Configuration section on page 5-2.
Configure the GP therm
ocouple info bar to display in the
desired location(s), as described in the EMS-D10 Pilot’s
User Guide > Global Configuration Settings > Info Item
Configuration
section.
After configuring alarms, press DOWN to select the LABEL 1 field. The first character of the
4-character name is highlighted. Press INC+ or DEC- to cycle through the numbers and letters
for the first character. When you have selected the desired letter, press SEL to move to the
next character. Repeat this for each of the characters in the contact name field. If desired, repeat
this for LABEL 2. If you leave LABEL 2 with its default “----” value, the temperature units are
displayed beneath the temperature bar’s label; otherwise, the value of LABEL 2 is displayed. Set
the SENSOR TYPE to J or K, depending on the thermocouple type used.
Sensor
Type
GP Temp Sensor
J J Type Thermocouple
K K Type Thermocouple
5-20 EMS-D10 Installation Guide