Installation Guide Owner manual
EMS Configuration
COOLANT TEMPERATURE
Sensor
Type
Coolant Temp
Sensor
Under the desired GP input number, set FUNCT to
COOL TEMP. Select the analog bar thresholds as
described in the Alarm and Color Threshold
Configuration on page 5-2. Set the SENSOR TYPE to
the correct n
umber using the sensor type table.
1 Dynon P/N 100409-001
C
hevrolet LS7 pre-
installed
2
3 Dynon P/N 100409-000
4 Rotax 801-10-1
Sensor
Type
COOLANT PRESSURE
Under the desired GP input number, set FUNCT to
COOL TEMP. Select the analog bar thresholds as
described in the Alarm and Color Threshold
Configuration on page 5-2. Set the SENSOR TYPE to
the correct n
umber using the sensor type table.
Coolant Pressure
Sensor
1 Dynon P/N 100411-000
OUTSIDE AIR TEMPERATURE SENSOR
Sensor
Type
OAT Sensor
Under the desired GP input number, set FUNCT to
OAT. Select the analog bar thresholds as described in
the Alarm and Color Threshold Configuration on page 5-
2. Set the SENSOR TYPE to the correct number using
the senso
r type table.
Dynon P/N 100433-000
(2-w
ire)
Dynon P/N 100433-001
(3-wire, when installed
as described on page 3-
13)
1
If you have installed a D
ynon Avionics OAT to a
General Purpose Input enter the EMS setup menu by
pressing SETUP > SENSOR > EMS GP INPUT. Set the
desired GP Input to OAT and select sensor type 1.
2 GRT OAT-01
Do not set the sensor type in the EFIS > SETUP
> OAT menu on any DSAB-connect EFIS instruments. Ensure that the INSTALLED
value in the EFIS OAT menu is set to N.
AILERON TRIM
Under the desired GP input number, set FUNCT to TRIM AILRN. There are no alarm thresholds
or any other setting required for aileron trim.
ELEVATOR TRIM
Under the desired GP input number, set FUNCT to TRIM ELEV. There are no alarm thresholds
or any other setting required for elevator trim.
RUDDER TRIM
Under the desired GP input number, set FUNCT to TRIM RUDR. There are no alarm thresholds
or any other setting required for rudder trim.
FLAP POSITION
Under the desired GP input number, set FUNCT to FLAP POS. There are no alarm thresholds or
any other setting required for flap position.
EMS-D10 Installation Guide 5-17