GP output table
General purpose inputs have a unique format in the data output stream. As shown in the table above, they each have 8
characters. 3 are used as a label for the function; 5 are used for the data. As noted above, general purpose inputs sourced
from the HS34 are not included in this table.
Description Units Label (3-Bytes) Example (5-Bytes)
Unused N/A XXXXX (‘X’s are output as place holders)
OAT ºF OAT 00123 (123 ºF) or –0123 (-123 ºF)
Carb Temp ºF CRB 00123 (123 ºF) or –0123 (-123 ºF)
Coolant Temp ºF CLT 00123 (123 ºF) or –0123 (-123 ºF)
Coolant Pressure PSI CLP 00123 (12.3 PSI)
Fuel Level 3 Gallons x 10 FL3 00123 (12.3 gal)
Fuel Level 4 Gallons x 10 FL4 00123 (12.3 gal)
CHT CHT
Aileron Trim
% of full
deflection
TRA
0061 (61%)
Elevator Trim
% of full
deflection
TRE
0061 (61%)
Rudder Trim
% of full
deflection
TRR
0061 (61%)
Flap Position º FLP 00010 (10º)
As an example, the following is one line of EMS data:
0012224826351340262441240122631320562191191OAT00090TRE-0061FLP0001020481378139214
061421143514503583533633743843951103D2