Instruction Manual

D10 and D100 Series Conversion To SkyView Guide Rev D Page 26
EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
26
GREEN/RED
MANIFOLD
PRESSURE
MANIFOLD
PRESSURE
No changes required.
27
(NO WIRE)
GENERAL
PURPOSE
THERMOCOUPLE
+ (J OR K)
GENERAL
PURPOSE
THERMOCOUPLE
1 + (J OR K)
No changes required.
28
(NO WIRE)
GENERAL
PURPOSE
THERMOCOUPLE
- (J OR K)
GENERAL
PURPOSE
THERMOCOUPLE
1 + (J OR K)
No changes required.
29
YELLOW/GREEN
EMS ALARM
LIGHT OUTPUT
EMS ALARM
LIGHT OUTPUT
No changes required.
30
BLACK
PC SERIAL
GROUND
GROUND
New capability - now a sensor
ground. Cut off the 9-pin
connector to use this wire.
If connected to PC (firmware,
data logs), no longer required.
31
WHITE/ORANGE
AUDIO OUTPUT
GENERAL
PURPOSE INPUT
13 (TYPE C)
New capability now a General
Purpose input.
If connected to audio output,
reroute this wire to SkyView
display. Because EFIS Audio
was mono, connect this wire to
both SkyView Display
PIN 13 AUDIO OUTPUT LEFT
and
PIN 31 AUDIO OUTPUT RIGHT
If a 10K potentiometer was
installed on this to adjust
volume, remove it (SkyView has
internal volume adjustment).
32
WHITE/GREEN
RPM LEFT
STANDARD
VOLTAGE RPM
LEFT
If connected to Rotax engine
(5
th
trigger coil), remove 30K
resistor.
If not connected to Rotax, no
changes required.