Pest Control Equipment User Manual
CONTROL PANEL INTERFACE INSTALLATION
Testing the Motorized Carriage and Wheel Clamp
Version 1 Control Panel Interface Installation and User Guide
1-29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TESTING THE MOTORIZED CARRIAGE AND WHEEL CLAMP
1 Replace the CPI cover if it was removed. Refer to page 1-6 for more information.
2 Plug the dyno into the power outlet.
3 Turn on the main breaker inside the CPI door.
Refer to “Connecting and Disconnecting Power to the Dyno” on page 1-3 for 
more information.
4 Using the Control Panel, press the carriage forward and backward buttons and 
verify that the motor does turn.
Refer to “Using the Motorized Carriage” on page 2-5 for more information on 
using the Control Panel Interface.
5 Place a stack of catalogs into the wheel clamp.
6 Using the Control Panel, press the close button and observe that the wheel clamp 
does close. Hold the button until the motor turns off and the status light is on 
steady.
7 Press and hold the right hand wheel clamp button then press the left hand button 
to open the clamp.
Refer to “Using the Wheel Clamp” on page 2-6 for more information on using the 
Control Panel.
Note: If your country requires you install the safety switch, please refer to the 
instructions in Appendix C.