Service manual
422 Trinix NXT — Installation and Service Manual
Section 13 — Trinix Fiber Option
Output Rear panel LEDs
Note The reclocker will not lock when in the force-bypass mode.
Number Color Indication
606 Green FPGA is loaded
637 Yellow Active board
518 Red Alarm Condition
910-940 Green Power indicators
Color Condition Indication
None Off No SFPs have been installed.
Red Solid Indicates an SFP alarm. This can be due to several errors, such as insuffi-
cient output power or excess output power, over or under temperature, and
over or under power supply voltages.
The alarm bits can be read through the Broadlinx console port.
Green Solid Indicates the reclocker is locked and the SFP is recognized with no alarms.
Yellow Solid Indicates the reclocker is not locked and the SFP is recognized with no
alarms.
Red and Yellow Blinking Indicates the reclocker is not locked. Indicates an unrecognized or invalid
SFP is installed. No SFP alarms will be reported if the LED is blinking red.
Red and Green Blinking Indicates the reclocker is locked and the input signal may be valid. Indicates
an unrecognized or invalid SFP is installed. No SFP alarms will be reported
if the LED is blinking red.
Green and Yellow Alternating blinking Indicates the reclocker is in the force bypass mode, or is not reliably locked,
Green and Off Alternating blinking Indicates the reclocker is locked and the output is disabled. Indicates an
unrecognized or invalid SFP is installed. No SFP alarms will be reported if
the LED is blinking red.
Yellow and Off Alternating blinking Indicates the reclocker is not locked and the output is disabled. Indicates an
unrecognized or invalid SFP is installed. No SFP alarms will be reported if
the LED is blinking red.