Service manual
396 Trinix NXT — Installation and Service Manual
Section 12 — Troubleshooting
Input boards - HI-3G
Ref Display Meaning
IN_USE DS610 Reserved for future use
XC_DONE DS521 Green The FPGA is configured.
Off Configure FPGA.
ALARM DS601 Red Master alarm for this board. A DC supply has failed to turn on
Off Board OK
7V DS3004 Green The Gain cell power is OK.
Off Check the Gain cell power.
3V3 DS3003 Green The Equalizer and Misc. power is OK.
Off Check the Equalizer and Misc. power.
2V5 DS3002 Green The SDI and Bus Driver power is OK.
Off Check the SDI and Bus Driver power.
-1V3 DS3001 Green The FPGA Core power is OK.
Off Check the FPGA Core power.
+3V3D DS968 Green The COM bus Digital logic is OK.
Off Check the COM bus Digital logic.
+3V3 DS1 Green The local 3.3 logic is OK.
Off Check the local 3.3 logic.
5V DS963 Green
The Main Conversion is OK.
Feeds 7v conversion.
Off Check the Main Conversion.