Trinix NXT — Installation and Service Manual 231
Trinix Asymmetrical Frames
be configured, by means of Dual In-line Package (DIP) switches, to match
the power supply configuration of each system.
Figure 138. TRX-SC Board
Configuration DIP Switches
The configuration DIP switches are located on the left side of the back of the
TRX-SC board (
Figure 139).
Note The DIP switches will be highlighted in red in the following TRX-SC board
examples in this appendix.
Figure 139. TRX-SC Configuration DIP Switch Location
The DIP switches will control the number of power busses and the number
of external power supply frames to monitor. Refer to
Table 50 for the con-
figuration DIP details.
Table 50. TRX-SC Configuration Switch Details
Switches Details
SW 1 = BUS A ENABLE
SW 2 = BUS A EXPANSION ENABLE (Future use)
SW 3 = BUS B ENABLE
SW 4 = BUS B EXPANSION ENABLE (Future use)
SW 5 = N/A
SW 6 = N/A
SW 7 = N/A
SW 8 = N/A
071827609_TRX-SC-3G-board_Configuration DIP Switch