Service manual
216 Trinix NXT — Installation and Service Manual
Section 3 — Hardware Installation
Figure 125. CC-2010 wiring. Reference: Assembly, CC-2010 Matrix Cable,” Grass Valley drawing
no. 01-032707-TAB
VDE EMI/RFI modifications to matrix cables
User-supplied matrix cables for VDE installations require a ferrite core over
each end of the cable, adjacent to the connector.
Figure 126. Matrix cable VDE modifications.
2. Set the Trinix INT XPT CNTL rear-panel DIP switch to Off (switch
open). See
Figure 127.
1 1
8
P1
DB15P
(male)
Shield (drain)
P2
DB15P
(male)
Red
9
Black
2
Yellow
10
Black
3
Green
11
Black
4
Blue
12
Black
5
White
13
Black
8
2
3
4
5
9
10
11
12
13
Twisted pairs
50 ft ( 15.2 m) max
Ferrite core
Ferrite core
Shield
Red
Black
Yellow
Black
Green
Black
Blue
Black
White
Black
Reset
Data
Clock
Ta k e
Confirm
Ground
Type 43 material
0.375 inch (9.53 mm) or larger inside diameter
0.95 inch (24.13 mm) length (or longer)
Type 43 material sources
Fair-Rite, part no. 2643625102
Fair-Rite Products Corp., P.O.Box J, Commercial Row,
Wallkill, NY 12589, USA; Tel. (914) 895-2055.
Chomerics, part no. 83-10-A637-1000
Chomerics Inc., 77 Dragon Ct., Woburn, MA 01888
USA; Tel. (617) 935-4850.