Installation manual

14 TRINIX — Release Notes
Version 3.2.0
Caveats
Before starting the Installation process, please read the following:
Web tools such as NetConfig cannot be used to install versions prior to
the 3.2.0 version of Broadlinx.
Protected paths are not monitored during firmware updates. If the
primary path fails during a firmware update, no fail-over switch will
occur.
Certain TRX-NXT-512x512 systems will require DIP switch changes to
operate properly with the 2.4 release (or newer) software. The S401-7
and S401-8 DIP switches on the DM-33501 and DM-33502 1.5G matrix
boards should be set to
ON. If the stickers are not present, these switches
should be set to
Off. The remaining six switches on S401 are always set
to
Off.
For multiple Trinix 128 or 256 frame systems only, the dip switch “A”
setting on the frame with the Broadlinx board that is driving the Com
Bus should be set to Open. This setting should be set to Closed on all
other frames in the system. This step is required when using Protected
Paths. For single frame operation the “A” switch must be set to the
Open position.
Certain steps of the following procedure will momentarily interrupt
switcher operations. These steps are preceded by a
Caution statement.
For more information, contact Grass Valley’s Technical support; see page 4.
Updating Compact Flash Cards
Compact Flash (CF) Memory cards are used to update Broadlinx. These
cards are read from the NR-33000 (Broadlinx) board. You must use at least
a 128MB CF memory card.