Specifications

AIR setups
Dynaudio Professional AIR reference manual – 2014-08-28 19
5.1 setup with Digital AES/EBU card
5.1 setup with Digital AES/EBU card
Slave
Left
Master
Left
surround
Master
Center
System Ctrl.
L + R C + LFELS + RS
Slave
Right
surround
Slave
Right
Sub
Subwoofer
Fig. 9: This illustration shows how to connect 5.1 digital setup with optional bass management.
Understanding and using this setup
This setup requires…
one Master monitor with the optional Digital AES/
EBU Input Card installed,
four Slave monitors (or Masters set as Slave) and
one subwoofer.
The Center monitor is set as the System Controller
by setting the TC Link button on the rear panel to
the “out” position.
The Center monitor receives all six channels on its
three AES/EBU connections.
The monitor’s Digital IN connection receives the
Center and LFE signals.
The digital input No. 2 on the I/O card receives the
left signal and the right signal.
The digital input No. 3 on the I/O card receives the
left surround signal and the right surround signal.
The right, left, left surround and right surround
monitor and the subwoofer receive their signal
via TC LINK RJ-45 connections from the Center
Master monitor.
A clock signal must be sent over the AES connec-
tion feeding the Center/LFE channels (or via BNC).
With no bass management, only the LFE signal is
fed to the Sub.
With bass management activated, low-frequency
information is extracted from the ve main chan-
nels below the set crossover frequency and fed to
the subwoofer.
The AIR Remote or a computer running the AIR
Control software can be connected to any available
TC LINK Out connection.