Product specifications

Smart LT Manual Dynatronix, Inc.
198-0853-02 Rev F Page 47 of 126
Use the following proceedure to select which run screen is displayed. The run screen selection is
retained through a power cycle (for example, if the meters were displayed when the unit was
powered off, then the meters will be displayed when the unit powers on). See A.4.Display Select
Menu for details on the “Display Select Menu”.
1) Press and hold both encoder switches until the display shows “diSP” “SEL”.
2) The “Display Select Menu” is indicated by showing “diSP” on the top display and the
currently selected run screen on the bottom display. Rotate the current encoder to
select the desired run screen. Then press the voltage encoder switch to exit the
“Display Select Menu” and view the selected run screen. Alternatively the “Display
Select Menu” will automatically exit and display the selected run screen if no
changes are made for several seconds.
6.6.1. Meters Run Screen
The meters run screen is displayed when “mtr” is selected from the “Display Select Menu” (see
6.6.Run Screens for details on using the “Display Select Menu”). The meters run screen shows
the voltage meter on the top display and the current meter on the bottom display. The SET lamp
is off when the meters are displayed.
The current or voltage setting can be displayed and changed by pressing the associated encoder
switch. The SET lamp will flash on and off when one or both settings are displayed. When a
setting is displayed the selected digit (blinking) can be adjusted by rotating the associated
encoder. Each press of the associated encoder switch advances the selected digit. When no
changes are made to the settings for a short period of time the display returns to the meter values
(SET lamp is off).
When the power supply is in operate mode and the meters are displayed (SET lamp is off) rotating
an encoder will adjust the least significant digit of the associated setting. The affect of the change
will be reflected by the associated meter if the output value changes.
The current and voltage settings cannot be adjusted while the power supply is in remote control
mode (RMT lamp is on).
6.6.2. Totalizer Run Screen
The totalizer run screen is displayed when “tot” is selected from the “Display Select Menu” (see
6.6.Run Screens for details on using the “Display Select Menu”). The top display indicates the
totalizer units and which portion of the totalizer is being displayed. Since the totalizer maximum
value is 99999999 (decimal point location is dependent on the totalizer settings) only half of the
totalizer value is displayed at a time. Rotating the voltage encoder while the totalizer run screen is
displayed will switch the bottom display between the upper (“Hi”) four digits and the lower (“Lo”)
four digits of the totalizer value. The totalizer accumulates any time there is current output by the
power supply. The SET lamp is off when the totalizer run screen is displayed. See 6.3.1.Totalizer
Configuration for details on how to configure and clear the totalizer.
The following table shows various totalizer run screen messages.
Top Display Text
Totalizer Units
Totalizer digits displayed
“tot AmP min Lo”
Amp Minutes
4 least significant digits
“tot AmP min Hi”
Amp Minutes
4 most significant digits
“tot AmP Hr Lo”
Amp Hours
4 least significant digits