Product specifications
Page 28 of 126 198-0853-02 Rev F
6.2.2. Menu Access
All menus are accessed by pressing and holding both encoder switches until the desired menu
title is displayed. Menus that contain an “End” sub menu item are exited by selecting “End”.
Menus with no “End” sub menu item are automatically exited after no changes are made for a
period of time, or the voltage encoder switch is pressed to accept the selection.
The unit configuration menu is accessed by pressing and holding both encoder switches when the
unit is powered on and releasing them after the display changes to “Unit” CFg”.
The display select menu is accessed from any run screen by pressing and holding both encoder
switches until the display changes to “diSP” “SEL” (approximately one second).
The setup menu is accessed from any run screen by pressing and holding both encoder switches
until the display changes to “Unit” “SEt” (approximately three seconds).
See Appendix A:Menu Tree for more details on menu access.
6.2.3. Menu Navigation
When a menu is displayed the SET lamp is illuminated (the SET lamp is off when a run screen is
displayed). Menu titles are displayed on the top display. Sub menu names and parameters are
displayed on the bottom display.
See Appendix A:Menu Tree for more details on menu navigation.
6.2.3.1. Entering and Exiting Sub Menus
Text that blinks on and off indicates a sub menu selection (SET lamp is on) or a parameter value
that can be changed (SET lamp blinks on and off). Rotate the current encoder to select the
desired sub menu. Press the voltage encoder switch to enter the selected sub menu.
To exit a menu or sub menu rotate the current encoder to select “End”, then press the voltage
encoder switch to exit the sub menu. If there is no “End” selection available press the voltage
encoder to accept the selection and exit the menu.
6.2.3.2. Changing Parameter Data
When parameter data is displayed the SET lamp blinks on and off. Parameter data can be text
(like “on” or “OFF”) or it can be numeric. If the parameter data displayed can be changed it will
blink on and off. In the case of numeric data only one digit will blink at a time and only one digit
can be changed at a time.
To change a text parameter rotate the current encoder to select the desired text value. Press the
voltage encoder switch to accept the value and return to the previous menu.
To change a numeric value rotate the current encoder to change the selected digit. Press the
current encoder switch to select a different digit. When the desired numeric value is displayed
press the voltage encoder switch to accept the value and return to the previous menu.