Product specifications

Smart LT Manual Dynatronix, Inc.
198-0853-02 Rev F Page 125 of 126
98
X
X
Voltage over tolerance alarm (CH1).
The difference between the voltage
reading and the voltage setting on
CH1 exceeded the tolerance setting
(reading greater than the voltage
setting).
Out of tolerance alarms self clear
at the start of a new cycle.
Optionally out of tolerance
alarms can be manually cleared
at any time, but will be set again
if the condition persists.
NO
YES
99
X
X
Voltage over tolerance alarm (CH2).
The difference between the voltage
reading and the voltage setting on
CH2 exceeded the tolerance setting
(reading greater than the voltage
setting).
Out of tolerance alarms self clear
at the start of a new cycle.
Optionally out of tolerance
alarms can be manually cleared
at any time, but will be set again
if the condition persists.
NO
YES
100
X
X
Voltage under tolerance alarm (CH1).
The difference between the voltage
reading and the voltage setting on
CH1 exceeded the tolerance setting
(reading less than the voltage
setting).
Out of tolerance alarms self clear
at the start of a new cycle.
Optionally out of tolerance
alarms can be manually cleared
at any time, but will be set again
if the condition persists.
NO
YES
101
X
X
Voltage under tolerance alarm (CH2).
The difference between the voltage
reading and the voltage setting on
CH2 exceeded the tolerance setting
(reading less than the voltage
setting).
Out of tolerance alarms self clear
at the start of a new cycle.
Optionally out of tolerance
alarms can be manually cleared
at any time, but will be set again
if the condition persists.
NO
YES
102
X
X
A complete power failure occurred
while the unit was in operate mode.
The output was disabled for an
unknown period of time (while the
power was off). This error code is
only reported if power failure alarms
are enabled.
Power failure alarms must be
manually cleared. Once a power
failure alarm is set it will remain
active (even through multiple
power on/off cycles) until it is
manually cleared.
NO
YES
103
X
X
Power was temporarily lost and then
recovered before a complete
shutdown occurred. Power was lost
and the output was disabled until
power was recovered. The period of
time that the output was disabled
depends on how long power was
lost, but was not more than the
maximum amount of time the supply
controls can remain active after
primary power has been lost. Note
that if this fault is set in combination
with error 102 then the total amount
of time that the output was disabled
cannot be determined since error 102
indicates a complete loss of power
where the controls are no longer
active. Error 102 and 103 can occur
together when primary power is lost
and recovered multiple times at
various intervals. This error code is
only reported if power failure alarms
are enabled.
Power failure alarms must be
manually cleared. Once a power
failure alarm is set it will remain
active (even through multiple
power on/off cycles) until it is
manually cleared.
NO
YES