B.1.18 Unit Info Command “u”:
@AA.a
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID), a =
Channel ID (always 0)
u0
Command character and Type 0=read, 1=set(n/a), 2=activate(n/a), 3=ack,
4=nak
#24,
Number of fields character and number of fields after the comma, excluding CRC
00,
Model Type Start model types start at 20. 20 = 1200W, 21 = 36kW
mdl
0123456,
serial number 01 is 2 digit year, 234 is day of year, 56 is unit build count
sn
750,
Amp Rating amps
fir
750,
Volt Rating volts
fvr
750,
Amp Rating amps (second channel, if present)
fir
750,
Volt Rating volts (second channel, if present)
fvr
6000,
unit on time minutes
ton
3000,
unit operate time minutes
topr
12345,
Unit amp hours ch1
ahr
0,
Unit amp hours ch2
ahr
3,
LT control panel firmware major version number 0-255 [in PT# 200-
1458-V301 the major version number is 3]
av1
0,
LT control panel firmware minor version number 0-255 [in PT# 200-
1458-V301 the minor version number is 1 (01)].
av2
1,
LT control panel firmware revision number 0-255 [the revision is not part
of the part number]
av3
6,
LT Boot loader major version number 0-255 [in PT# 200-0458-V601 the
major version number is 6]
bv1
0,
LT Boot loader minor version number 0-255 [in PT# 200-0458-V601 the
minor version number is 1 (01)]
bv2
1,
LT Boot loader revision number 0-255 [the revision is not part of the part
number]
bv3
200,
LT control panel firmware part number class [in PT# 200-1458-V301, the
class is 200]
ap1
1458,
LT control panel firmware part number type [in PT# 200-1458-V301, the
type is 1458]
ap2
301,
LT control panel firmware part number version [in PT# 200-1458-V301 the
version is 301]
ap3
200,
LT boot loader firmware part number class [in PT# 200-0458-V601, the
class is 200]
bp1