Product specifications
Smart LT Manual Dynatronix, Inc.
198-0853-02 Rev F Page 113 of 126
Readings Command: (cont.)
Examples of Readings Command:
read readings command from unit 1.
@01.0d0#0,54321
ACK readings command with text delimiters.
@01.1d3#12,1opr,1rem,8.2afi,10.23afv,1reg,2xc,10.25xtot,1234tot,75fdty,35tmp,1stf,0alrm,54321
Notes:
1. The usable resolution of any value is limited to the accuracy and precision of the power supply as
indicated in the power supply manual.
2. A non-zero error flag indicates errors are present. Use the error status message “m” to determine
which errors are present.
3. Using the global unit address (00) has no affect, no response is sent to commands directed to the
global unit address.
4. The error flag is set as soon as any active errors are set by the LT controller. This flag will remain
set (1) until the error or errors are read using the error status command “m”. This flag does not
indicate that errors are currently active, only that errors have been set and have not be read since
they were set. To track currently active errors the error status command “m” should be used any
time the error flag is set in the readings command.
5. See the host State command “a” for more information on simulation mode.