Product specifications

Page 112 of 126 198-0853-02 Rev F
B.1.14 Readings Command “d”:
@AA.a
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global
ID), a = Channel ID ( 0 to 2; 0 is a global channel)
d0
Command character and Type 0=read, 1=set(n/a), 2=activate(n/a), 3=ack,
4=nak
#12,
Number of fields character and number of fields after the comma, excluding
CRC
1,
supply state 0=standby, 1=operate, 2= pause (cycle is paused and output
is disabled)
opr
1,
Local/Remote state 0 = local, 1 = remote,
rem
8.2,
average forward current amps
afi
10.23,
average forward voltage volts
afv
0,
Regulation 0 = not regulating (no output), 1 = voltage, 2 = current
reg
2,
XTC Mode (0=manual, 1=RTC, 2=ATC)
xc
20.5,
XTC Reading Amp time or Real time remaining in the currently running
ATC or RTC cycle - units are dependent on the XTC settings in the setup
command
xtot
1234,
Totalizer Value units are dependent on the totalizer settings in the setup
command
tot
75,
Cooling Fan Speed 0 to 100%
fdty
35,
Heat Sink Temperature degrees C (65535 if there is an error with the
sensor, an error code will also be reported in the alarm status command
“m”)
tmp
0,
Status Flags
Bit 0 = End of Cycle (1 = End of Cycle)
Bit 1 = Low Bus Voltage (1 = Low bus voltage, probable primary power
loss)
Bit 2 = Output Inhibit (1= hardware interlock is active, front panel inhibit
LED is on)
Bit 3 = Simulation Mode (1 = Simulation Mode is active)
Bits 4 to 15 Reserved for future use
stf
0,
alarm flag 0 = no alarms, 1 = one or more alarm codes have not been
read (see the alarm status command “m”)
alrm
CRC
CRC value in ascii decimal
crlf
Carriage return and Line feed (0x0D 0x0A)