Product specifications

Page 80 of 146 198-1600-00 Rev F
A.2 Menu Navigation







.
.
.
.
Menu Selection:
A menu selection is shown when the SET lamp is on (not blinking). The top display shows the menu name;
in the example below “tOL” indicates the tolerance menu. The bottom display indicates the sub menu; in
the example below “CUrr” indicates current. When the bottom menu blinks rotating the current encoder
changes the sub menu selection. Pressing the voltage encoder switch selects the sub menu; in this case the
current tolerance.
A setting is shown when the SET lamp is blinking. In the example below the current tolerance setting
“I.tOL” is viewed. When a setting is displayed and blinking the associated encoder can be used to change
the setting. If only one digit of the setting is blinking then the setting is changed one digit at a time.
A setting value is accepted and control returns to the parent menu when the voltage encoder switch is
pressed.
Numeric Values:
Numeric values are modified one digit at a time. The blinking digit is the currently selected digit. Rotating
the associated encoder changes the value of the selected digit. Each press of the associated encoder switch
advances to the next digt.

Rotating the current
encoder changes the sub
menu selection from
current “CUrr” to voltage
“VOLt” tolerance.




Cycle Time Control =
Manual Time Control
Cycle Time Control =
Real Time Control

Cycle Time Control =
Amp Time Control
Text Values:
In the example below the cycle control menu is shown. The cycle control type is a text value. When
a text setting is shown the SET lamp blinks. If the text setting can be changed it will blink. Rotating
the associated encoder changes the text setting. Here the cycle control type is changed.
Pressing the voltage
encoder switch enters
the cycle control menu.
Rotating the current
encoder changes from
manual “mAn” to real
time control “rtc”.
Rotating the current
encoder changes from
real time control “rtc”
to amp time control
“Atc”.
Pressing the voltage
encoder switch enters
the current tolerance
menu.
Rotating the current
encoder changes the
blinking digit from zero
to one.
Rotating the current
encoder changes the
blinking digit from zero
to one.
Pressing the current
encoder switch
advances the selected
digit by one.
Pressing the voltage
encoder while the cycle
control type is viewed
accepts the current
value and returns to the
main cycle menu.
Pressing the voltage
encoder while the
current tolerance is
viewed accepts the
value and returns to the
main tolerance menu.