Product specifications
Diamond 36kW Manual Dynatronix, Inc.
198-1600-00 Rev F Page 57 of 146
changes are made to the settings for a short period of time the display returns to the meter values
(SET lamp is off).
When the power supply is in operate mode and the meters are displayed (SET lamp is off) rotating
an encoder will adjust the least significant digit of the associated setting. The affect of the change
will be reflected by the associated meter if the output value changes.
The current and voltage settings cannot be adjusted while the power supply is in remote control
mode (RMT lamp is on).
6.6.2. Totalizer Run Screen
The totalizer run screen is displayed when “tot” is selected from the “Display Select Menu” The
top display indicates the totalizer units and which portion of the totalizer is being displayed. Since
the totalizer maximum value is 99999999 (decimal point location is dependent on the totalizer
settings) only half of the totalizer value is displayed at a time. Rotating the voltage encoder while
the totalizer run screen is displayed will switch the bottom display between the upper (“Hi”) four
digits and the lower (“Lo”) four digits of the totalizer value. The totalizer accumulates any time
there is current output by the power supply. The SET lamp is off when the totalizer run screen is
displayed. See 6.3.1.Totalizer Configuration for details on how to configure and clear the totalizer.
The following table shows various totalizer run screen messages.
Top Display Text
Totalizer Units
Totalizer digits displayed
“tot AmP min Lo”
Amp Minutes
4 least significant digits
“tot AmP min Hi”
Amp Minutes
4 most significant digits
“tot AmP Hr Lo”
Amp Hours
4 least significant digits
“tot AmP Hr Hi”
Amp Hours
4 most significant digits
6.6.3. Cycle Run Screen
The cycle run screen is displayed when “CyCL” is selected from the “Display Select Menu”. The
cycle run screen shows a count down of the time remaining in the currently running or paused
timed cycle (RTC or ATC). The top display indicates the type of cycle (RTC or ATC), the units of
the cycle time, and which portion of the cycle time is being displayed. Since the maximum cycle
time is 99999999 (decimal point location is dependent on the cycle settings) only half of the cycle
time is displayed at a time. Rotating the voltage encoder while the cycle run screen is displayed
will switch the bottom display between the upper (“Hi”) four digits and the lower (“Lo”) four digits of
the cycle time.
The cycle preset time setting can be viewed or changed from the cycle run screen (the cycle
preset time setting can also be changed from the cycle setup menu). Pressing the current
encoder will display the cycle preset time (SET lamp is flashing on and off). Only half of the cycle
preset is displayed at a time. The upper four digits are displayed when the display shows “SEt.H”,
the lower four digits are displayed when the display shows “SEt.L. Rotate the voltage encoder to
select between the upper and lower half of the cycle preset. When the target cycle time is
displayed the currently selected digit (blinking) can be changed by rotating the current encoder.
Each press of the current encoder advances the selected digit. When no changes are made to
the cycle preset for a short period of time the display returns to the time remaining in the cycle.
The cycle preset cannot be changed while the power supply is in operate mode (OPER/STBY
lamp is on), and the cycle preset cannot be changed while the power supply is in remote control
mode (RMT lamp is on).
See 6.4.2.Timed Cycle Control (RTC or ATC) for details on timed cycle settings.