Product specifications

Diamond 36kW Manual Dynatronix, Inc.
198-1600-00 Rev F Page 43 of 146
4) If “yES” was selected a warning screen is displayed. The warning screen shows
“CHng” on the top display and “ALL” on the bottom display. The warning message is
displayed for a short period of time and can be skipped by pressing the voltage encoder
switch.
5) After the warning message is displayed a confirmation screen is displayed. The top
display shows “CHng ALL to dFLt” and the bottom display shows the confirmation
selection. Rotate the current encoder to change the confirmation selection. Select
“yES” to reset all settings to default values or “no” to cancel. Press the voltage encoder
switch to accept the selection and exit the “Set Defaults System Menu” and return to the
“System Configuration Menu”.
6) From the “System Configuration Menu” rotate the current encoder until the display
shows “SyS” “End”. Then press the voltage encoder switch to exit the “System
Configuration Menu” and return to the “Unit Configuration Menu.
7) If any settings were changed in the “System Configuration Menu” you will be prompted
to store the changes. Select “yES” to accept the changes or “no” to cancel the
changes. You must select “yES” to accept the default values.
6.3.11. Calibration
The “Calibration Menu” is located within the “Unit Configuration Menu (see 6.3: Unit
Configuration). See 10: Calibration Procedure for a details on the calibration menu and how to
calibrate the power supply.