Product specifications
Diamond 36kW Manual Dynatronix, Inc.
198-1600-00 Rev F Page 137 of 146
Appendix C: Error Codes
When a fault condition occurs the FAULT lamp on the front panel illuminates. The
display will switch back and forth between the normal read back meters and an error
code. If multiple error codes are active each active error code is displayed one at a time
until all active error codes have been displayed. See 6.5.Error Messages for more
details regarding the display of error codes. The following is a list of possible error
codes.
NOTE: A list of active errors and error history information can be viewed using the host
port. See B.1.17:Error Status Command “m”: and B.1.18:Error History Command “h”:
for more information.
Front Panel Display Error Code Format:
“NNN.SS”
“NNN” = Error Number
“SS” = Source
Host Port Interface Error Code Format:
“ssssEEEEEEEEEEEE”
“EEEEEEEEEEEE” = 12 bit error number
“ssss” = 4 bit error source
Error
Number
Source
Fault Description
Corrective Action
Output
Disabled
Logged to Error
History
1
System
(0)
DSP detects brownout caused a
reset
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO
YES
2
System
(0)
DSP detects a watch dog timeout
caused reset
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO
YES
3
N/A
N/A
N/A
N/A
N/A
4
System
(0)
DSP detects a reset because of
the MEM CLR line
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO
YES
5
System
(0)
DSP illegal op code trap
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO
YES
6
System
(0)
DSP trap conflict trap
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO
YES
7
System
(0)
DSP oscillator fail trap
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO
YES
8
System
(0)
DSP address error trap
Cycle power or manually clear
fault. If fault continues report to
Dynatronix, Inc.
NO