Product specifications

Page 136 of 146 198-1600-00 Rev F
2,
Graphic display software minor version number
dv2
3,
Graphic display software revision number
dv3
1,
FPGA serial protocol major version number
sp1
1,
FPGA serial protocol minor version number
sp2
CRC
CRC value in ascii decimal
Crlf
Carriage return and Line feed (0x0D 0x0A)
Unit Info Command: (cont.)
Examples of Unit Command:
read unit command.
@01.0u0#0,54321
ACK read unit command with default descriptor text delimiters.
@01.0u3#28,1pv1,0pv2,20mdl,712647sn,112245ton,3av1,0av2,0av3,
3bv1,1bv2,2bv3,200ap1,1458ap2,300ap3,200bp1,458bp2,301bp3,1hv1,0hv2,0hv3,1fv1,0fv2,0fv3,1dv1
,0dv2,0dv3,1sp1,2sp2,54321
Notes:
1. The serial number is a seven digit number like 0123456 01 is 2 digit year, 234 is day of year
(ordinal date), 56 is day unit (next consecutive number of unit serialized that day).
2. The channel ID ‘a’ should always be zero.
3. In systems where there is no graphic display used (standard pots and meters operator interface is