Product specifications

Diamond 36kW Manual Dynatronix, Inc.
198-1600-00 Rev F Page 13 of 146
OUTPUT PROTECTION
Software power supply does not accept commands in
excess of its maximum current or voltage rating.
CONTROLS
Remote control (standard encoders/meters or optional
graphic touch screen), 4-20 mA, 0 5 V, or 0 10 V
Isolated Analog Control, and RS485 Host Port.
ENVIRONMENTAL CONDITIONS
INDOOR USE ONLY: FOR USE IN CONTROLLED,
NON-CONDENSING ENVIRONMENT
Operating Temperature: 0 40 C
Storage Temperature: -20 85 C
LOAD REGULATION
+/- 0.5% of setting or +/- 0.05% of max rating
LINE REGULATION
+/- 0.5% of setting or +/- 0.05% of max rating
RIPPLE
No more than 1% RMS of maximum rated output
voltage.
COOLING
Forced air cooling: Leave a minimum of 2 inches
clearance in the front and rear of the power supply.
ENCLOSURE
304 Stainless Steel Material
SIZE
34” (836.6 mm) H x 17” (431.8 mm) W x 24” (609.6
mm) D (Footprint) (28” (711.2 mm) D (including
Busbars and Connectors))
WEIGHT
Approximately 300 lbs (150 lbs for 18kW)