13. Waveform names will be included in the reply to a read request onlyif delimiter text has been
enabled using the āiā command. Waveform names can be written with a set command regardless of
whether or not text delimeters have been enabled.
14. To provide the most accurate duplication of the waveform at the output all polarity changes should
occur at zero current output. The reversing bridge switches at the start of any segmen where a
polarity change occurs, therefore the reversing bridge will never switch in the middle of segment
execution. Any time a polarity change occurs the power supply output will go to zero prior to the
start of the segment having the polarity change and the segment will begin to run after the bridge
polarity changes. Therefore the most acurate duplication of a waveform having polarity changes
occurs when the segment prior to a polarity change has a zero current setting.