Product specifications

Page 118 of 146 198-1600-00 Rev F
B.1.12 Setup Command “s”:
@AA.a
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID),
a = Channel ID ( 0 to NUM_CHANNELS; 0 is a global channel)
s0
Command character and Type 0=read, 1=set, 2=activate (n/a), 3=ack,
4=nak
#21,
Number of fields character and number of fields after the comma, excluding
CRC.
100.0,
Forward Current Setting amps (not used when the output waveform type is
set to 2 (custom))
fi
12.25,
Forward Voltage settting volts (not used when the output waveform type is
set to 2 (custom))
fv
0,
Current Tolerance - Percent of Setting (0 to 100, 0 = disable tolerance
checks)
it
0,
Voltage Tolerance Percent of Setting (0 to 100, 0 = disable tolerance
checks)
vt
0,
XTC Control (0 = manual, 1 = RTC, 2 = ATC)
xc
1,
XTC Units (0=reserved, 1=ATC Amp Min, 2=ATC Amp Hr, 3=reserved,
4=RTC Min, 5=RTC Hr)
xn
0,
XTC Resolution (0=xxxx, 1=xxx.x, 2=xx.xx, 3=x.xxx)
xr
0,
XTC Preset (0 to 99999999, 0 to 9999999.9, 0 to 999999.99, or 0 to
99999.999, units and resolution are dependent on the xtc units and xtc
resolution specified in this command)
xs
0,
Current Ramp Preset (0 300.0 sec)
Irs
0,
Voltage Ramp Preset (0 300.0 sec)
vrs
0,
Pulse On Time (0 6.553 sec, 0 = DC) (only used when the output waveform
type is set to 1 (pulse))
pon
0,
Pulse Off Time (0 6.553 sec, 0 = DC) (only used when the output waveform
type is set to 1 (pulse mode))
poff
0,
Active Waveform Index (1 to 10) (only used when the output waveform type is
set to 2 (custom))
wv
0,
Home Link (1 to 40 = start link for custom wave form operation) (only used
when the output waveform type is set to 2 (custom))
hlnk
0,
Output Waveform Type (0 = DC, 1 = Standard Pulse, 2 = Custom)
wf
100.0,
Reverse Current Setting amps positive value (not used when the output
waveform type is set to 2 (custom))
ri
12.25,
Reverse Voltage settting volts positive value (not used when the output
waveform type is set to 2 (custom))
rv
0,
Reverse Pulse On Time (0 6.553 sec, 0 = DC) (only used when the output
waveform type is set to 1 (pulse))
rpon
0,
Reverse Pulse Off Time (0 6.553 sec, 0 = DC) (only used when the output
waveform type is set to 1 (pulse mode))
rpoff
0,
Forward Reading type (0 = Period Average, 1 = Real Time)
frd
0,
Reverse Reading type (0 = Period Average, 1 = Real Time)
rrd
CRC
CRC value in ascii decimal
crlf
Carriage return and Line feed (0x0D 0x0A)