Product specifications
Diamond 36kW Manual Dynatronix, Inc.
198-1600-00 Rev F Page 111 of 146
01
0
Directed to all channels on unit 1
99
0
Directed to all channels on unit 99
02
1
Directed to channel 1 on unit 2
For single channel supplies set the channel ID to one.
No response is sent to commands directed to the global unit ID (00).
B.1.6 Communications Settings (factory default) – RS485
Baud Rate
Bits
Parity
Stop Bits
Handshake
*115200
8
none
1
none (master-slave)
The RS485 host port can be operated on a multi-drop bus (multiple power supplies connected
to a single host, all using the same communications cable). The host (master) is always
listening unless sending a command. Slave units are always listening for commands unless
sending a response. Slave units only respond to commands that contain their address.
* The baud rate is selectable, see B.1.19:Unit Settings Command “t”: to set the baud rate using
the host port. See 6.3.2:Host Port Configuration to set the baud rate using the control panel.